Trouble or fault Possible cause Action to be taken
No fastener is driven. Fastener or fasteners jammed in
the fastener guide
First remove the cartridge strip
and then remove the jammed
fastener.
Avoid shear breakages of the
fasteners. Avoid missing the
beam. It may be necessary to
mark the position of the beam
better in future.
Base plate cannot be
screwed fully into place.
The piston stopper is fitted the
wrong way round
Unscrew the base plate, insert
the piston stopper the right way
round and screw the base plate
on again page 14.
The piston guide is clogged with
dirt behind the connecting thread.
Clean the piston guide.
Lubricate the connecting
thread.
The tool cannot be pressed
fully against the working sur-
face
The rotating sleeve is not fully
closed.
Close the rotating sleeve.
page 11
The nail detector is jammed. Clean the base plate and
remove all foreign objects.
Take care to ensure adequate
lubrication of the fastener strip
guides with Hilti lubricant spray.
Part of the nail detector is broken. Check for correct operation of
the nail detector by checking
that the tool is ready for use
page 9.
No fasteners loaded in the tool Load the tool with fasteners.
9 Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
10 Manufacturer’s warranty
Please contact your local Hilti representative if you have questions about the warranty conditions.
11 FCC statement (applicable in US) / IC statement (applicable in Canada)
This device complies with Part 15 of the FCC Rules and RSS-210 of lC. Operation is subject to the following
two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired
operation.
12 Further information
For more information on operation, technology, environment and recycling, follow this link:
qr.hilti.com/manual?id=2194400&id=2194029
This link is also to be found at the end of the documentation, in the form of a QR code.

Other manuals for Hilti DX 9–ENP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti DX 9–ENP and is the answer not in the manual?

Hilti DX 9–ENP Specifications

General IconGeneral
BrandHilti
ModelDX 9–ENP
CategoryPower Tool
LanguageEnglish

Related product manuals