10 English 2235450
*2235450*
SF 2-A12 SF 2H-A12
Ø drill bit (hardwood)
3/64 in …
25/64 in
3/64 in …
25/64 in
Ø drill bit (metal)
3/64 in …
15/64 in
3/64 in …
15/64 in
Ambient temperature for opera-
tion
−17 ℃ … 60 ℃
(1 ℉ … 140 ℉)
−17 ℃ … 60 ℃
(1 ℉ … 140 ℉)
Storage temperature
−20 ℃ … 70 ℃
(−4 ℉ … 158 ℉)
−20 ℃ … 70 ℃
(−4 ℉ … 158 ℉)
4.2 Battery
Battery operating voltage
10.8 V
Ambient temperature for operation
−17 ℃ … 60 ℃
(1 ℉ … 140 ℉)
Storage temperature
−20 ℃ … 40 ℃
(−4 ℉ … 104 ℉)
Battery charging starting temperature
−10 ℃ … 45 ℃
(14 ℉ … 113 ℉)
5 Preparations at the workplace
CAUTION
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or
before changing accessories.
Observe the safety instructions and warnings in this documentation and on
the product.
5.1 Charging the battery
1. Before charging the battery, read the operating instructions for the
charger.
2. Make sure that the contacts on the battery and the contacts on the
charger are clean and dry.
3. Use an approved charger to charge the battery.
Printed: 19.09.2019 | Doc-Nr: PUB / 5509387 / 000 / 01