Product type | Digital Output Module |
---|---|
Number of channels | 32 |
Rated voltage | 24 V DC |
Current per channel | 0.5 A |
Short-circuit protection | Yes |
Galvanic isolation | Yes |
Protection class | IP20 |
Connection type | Screw terminal |
Describes the manual's organization and additional documents.
Identifies intended readers and required knowledge for the manual.
Explains formatting used in the document for readability.
Details how safety notes are presented and their meaning.
Explains the presentation of helpful tips and tricks.
Defines the purpose and application of HIMax components.
Lists environmental conditions for proper module operation.
Outlines precautions to prevent damage from electrostatic discharge.
Identifies potential sources of residual risk in the system.
Emphasizes adherence to local safety rules and protective equipment.
Describes system behavior and actions during emergencies.
Explains how the module ensures its safety function.
Describes how the module behaves when faults occur.
Lists items included and not included in the module's delivery.
Describes the information provided on the module's type label.
Explains the module's internal structure and components.
Illustrates the module's functional block diagram.
Shows the location and appearance of the module's LED indicators.
Details the meaning of module status LEDs (Run, Error, Stop, Init).
Explains the system bus status LEDs.
Describes the I/O channel status LEDs.
Lists key technical specifications and product data.
Introduces available connector boards for the module.
Explains the mechanical coding system for connector boards.
Details the coding positions for specific connector boards.
Shows connector boards using screw terminals.
Provides detailed terminal assignments for screw terminal boards.
Illustrates connector boards that use cable plugs.
Details pin assignments for cable plug connector boards.
Describes the system cable used for connections.
Explains the coding mechanism for cable plugs.
Provides guidelines for installing the module correctly.
Instructions on how to handle unused outputs to prevent issues.
Detailed steps for installing and uninstalling the module.
Steps and tools for installing a connector board.
Procedures for installing and removing the module from the base plate.
Explains the module's short-circuit detection and configuration.
Provides recommended settings for line monitoring and SC interval.
Guides on how to configure the module using the SILworX tool.
Details statuses and parameters within the 'Module' tab of SILworX.
Explains system parameters in the 'I/O Submodule DO32_01' tab.
Describes system parameters for each digital output channel.
Explains the coding for the Submodule Status variable.
Details the coding for the Diagnostic Status variable.
Outlines permitted wiring methods for the module's outputs.
Illustrates the 1-pole wiring method for actuators.
Shows the 2-pole wiring method for actuators.
Describes how to wire actuators redundantly.
Guidance on connecting inductive loads and protective circuits.
Explains actuator connection using a field termination assembly.
Describes how the module is handled and operated.
Explains how to read module status and diagnostic messages.
Outlines general maintenance actions for the module.
Instructions for updating the module's operating system.
Specifies requirements for periodic proof testing.