Accuracy Table
AC+DC voltage (Measurement value/MAX/MIN/AVG)
Range
(Accuracy
guarantee range)
Resolution
Accuracy
guarantee
frequency range*
Measurement accuracy Input impedance
(DC input,
AC 50 Hz input)
Filter off Filter on
6.000 V
(0.000 V
to 0.299 V)
0.001 V 10 Hz≤f<45 Hz ±1.5% rdg.±0.023 V ±2.0% rdg.±0.023 V DC: 6.7 M
Ω
±5%
AC: 3.2 M
Ω
±5%
DC,
45 Hz≤f≤66 Hz
±1.0% rdg.±0.023 V ±1.5% rdg.±0.023 V
66 Hz<f≤1 kHz ±1.5% rdg.±0.023 V -
6.000 V
(0.300 V
to 6.000 V)
0.001 V 10 Hz≤f<45 Hz ±1.5% rdg.±0.013 V ±2.0% rdg.±0.013 V DC: 6.7 M
Ω
±5%
AC: 3.2 M
Ω
±5%
DC,
45 Hz≤f≤66 Hz
±1.0% rdg.±0.013 V ±1.5% rdg.±0.013 V
66 Hz<f≤1 kHz ±1.5% rdg.±0.013 V -
60.00 V
(3.00 V to
60.00 V)
0.01 V 10 Hz≤f<45 Hz ±1.5% rdg.±0.13 V ±2.0% rdg.±0.13 V DC: 6.1 M
Ω
±5%
AC: 3.1 M
Ω
±5%
DC,
45 Hz≤f≤66 Hz
±1.0% rdg.±0.13 V ±1.5% rdg.±0.13 V
66 Hz<f≤1 kHz ±1.5% rdg.±0.13 V -
600.0 V
(30.0 V to
600.0 V)
0.1 V 10 Hz≤f<45 Hz ±1.5% rdg.±0.7 V ±2.0% rdg.±0.7 V DC: 6.0 M
Ω
±5%
AC: 3.0 M
Ω
±5%
DC,
45 Hz≤f≤66 Hz
±1.0% rdg.±0.7 V ±1.5% rdg.±0.7 V
66 Hz<f≤1 kHz ±1.5% rdg.±0.7 V -
1000 V
(50 V to
1000 V)
1 V 10 Hz≤f<45 Hz ±1.5% rdg.±7 V ±2.0% rdg.±7 V DC: 6.0 M
Ω
±5%
AC: 3.0 M
Ω
±5%
DC,
45 Hz≤f≤66 Hz
±1.0% rdg.±7 V ±1.5% rdg.±7 V
66 Hz<f≤1 kHz ±1.5% rdg.±7 V -
Auto range movement threshold: 6000 counts or more for upper range, 540 counts or less for lower range.
* Frequency range of 10 Hz≤f<20 Hz is designed value.