EasyManua.ls Logo

Hioki IR4057-50 - Page 32

Hioki IR4057-50
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Using the L9788-10 Test Lead with Remote Switch (Red)
Replacing the Tip Pin (optional) for the L9788-10
When the tip pin of the L9788-10 Test Lead with Remote Switch
(Red) (option) is worn out or broken, it can be replaced. The tip pin
can be purchased via authorized Hioki distributor or reseller.
OFF
1
Turn off the rotary switch and
disconnect the L9788-10.
L9788-90 Tip Pin
Wrench
(size: 7 mm width)
2
Remove the tip pin by rotating
with a wrench.
3
Attach the new tip pin to the
L9788-10 by rotating with a
wrench.
(Tightening torque: 0.3 N·m)
4
Check the operation.
Measure a measuring object of known
values and use after checking that the
resistance is correct.
Attaching the L9788-92 Breaker Pin
Remove the sleeve of the L9788-10 and attach the breaker pin.
Fully insert.
L9788-92 Breaker Pin
Removing and attaching the test lead sleeves
Safely store the removed sleeves so as
not to lose them. (p. 11)
HIOKI IR4057B961-00

Related product manuals