3
About the Notations Used in This Manual
Notations related to standards compliance
Indicates compliance with the Waste Electrical and Electronic Equipment (WEEE)
Directive in EU member nations.
Li-ion
Indicates that the instrument is targeted for recycling under the Act on the Promotion of
E󰀨ective Utilization of Resources.
Indicates that the instrument complies with standards imposed by EU directives.
Other notations
Indicates useful advice concerning instrument performance and operation.
*
Instructs the reader to see below for additional information.
Indicates the default setting. When initialized, the instrument will revert to this value.
(p. ) Indicates the page number to reference.
Bold The names of control keys are printed in bold.
[ ]
The names of user interface elements on the screen are enclosed in brackets ([ ]).
Windows
Unless otherwise noted, the term “Windows” is used generically to refer to Windows 7,
Windows 8, and Windows 10.
S/s
For this instrument, the number of times the analog input signal is digitized is indicated
in samples per second (S/s).
Example: 20 Ms/s (20 megasamples per second) signies 20×10
6
samples per second.
Accuracy
Hioki denes tolerances for measured values in terms of f.s. (full scale), as indicated below.
f.s.
Maximum display value, scale magnitude
Indicates the maximum display value or scale magnitude. Generally speaking, the f.s.
gure indicates the range in current use.
Example: f.s. for the 1 V range = 1 V
HIOKI LR8450A963-02

Table of Contents

Other manuals for Hioki LR8450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki LR8450 and is the answer not in the manual?

Hioki LR8450 Specifications

General IconGeneral
ModelLR8450
CategoryData Loggers
Dimensions330 mm (12.99 in) W × 221 mm (8.70 in) H × 120 mm (4.72 in) D
WeightApprox. 2.8 kg (excluding battery)
Operating Temperature0 to 40 °C (32 to 104 °F), 80% RH or less (no condensation)
Sampling Rate1 ms to 1 hr
MemoryInternal memory
InterfaceUSB, Ethernet
Power SupplyAC adapter or battery
Measurement RangeVaries with module
AccuracyVaries with module
Storage MediaSD card
Memory CapacityInternal memory
Input TypeVoltage, temperature
Temperature MeasurementVaries with module
Communication InterfaceUSB, Ethernet
Measurement ChannelsUp to 120 channels (with optional input modules)