Installation EAGLE One
Release
03
07/2014
13
CONTROL DRAWING for EAGLEONE and TOFINOXE Series
according to the European Directive 94/9/EC
Rev. 0 Document No.: 000174247DNR Page 1/2
MSP30 / MSP32
Ordinary Location, Non-Hazardous Area,
1 2 3 4
4 3 2 1
The earth conductor must be
at least of the same wire size
(mm² or AWG) as the supply
conductors.
THE Fault Relays are tested as Sealed Device
according to ATEX EN 60079-15. Switching
current max. 1 A, (resistive load)
Switching voltage max. 60 VDC or 30 VAC
FAULT contacts
USB pin 4
USB pin 1
Any
EAGLEONE-0200xxx or
TOFINOXE-0200xxx device
Ambient Temperature rating:
Ta : 0°C to +60°C for “S” types
Ta: -40°C to +70°C for “T” or “E” types
- refer to the type designation on the device
(item 18 of product code: “Temperature range”).
Nonincendive field wiring parameters:
THE USB POWER SUPPLY CONTACTS ARE
DEPENDENT UPON THE FOLLOWING
ENTITY PARAMETERS:
WARNING: Exclusively use ACA USB devices