Ring Redundancy
Redundanz L2P
Release
5.0
04/09
3.2
Example of MRP-Ring
31
Note: Configure all the devices of the MRP-Ring individually. Before you
connect the redundant line, you must complete the configuration of all the de-
vices of the MRP-Ring. You thus avoid loops during the configuration phase.
Set up the network to meet your requirements.
You configure all 6 ports so that the transmission speed and the duplex
settings of the lines correspond to the following table:
Bit rate 100 Mbit/s 1000 Mbit/s
Autonegotiation
(automatic configuration)
off on
Port on on
Duplex Full
Table 3: Port settings for ring ports
Select the Redundancy:Ring Redundancy dialog.
Under “Version”, select MRP.
Define the desired ring ports 1 and 2 by making the corresponding
entries in the module and port fields. If it is not possible to enter a
module, then there is only one module in the device that is taken
over as a default.
Display in “Operation” field:
forwarding: this port is switched on and has a link.
blocked: this port is blocked and has a link.
disabled: this port is switched off
not connected: this port has no link.

Other manuals for Hirschmann MACH 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 100 and is the answer not in the manual?

Hirschmann MACH 100 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 100
CategorySwitch
LanguageEnglish

Related product manuals