Sub-Ring (RSR20, RSR30, MACH1000)
Redundanz L2P
Release
5.0
04/09
41
4 Sub-Ring
(RSR20, RSR30, MACH1000)
The Sub-Ring concept enables you to easily couple new network segments
to suitable devices in existing redundancy rings (basis ring). The devices of
the basis ring to which the new Sub-Ring is being coupled are known as Sub-
Ring Managers (SRM).
Figure 15: Example of a Sub-Ring structure
1 Blue ring = basis ring
2 Orange ring = Sub-Ring
SRM = Sub-Ring Manager
RM = Ring Manager
Note: The following devices support the Sub-Ring Manager function:
–RSR20/RSR30
MACH 1000
In a Sub-Ring, you can integrate all devices that support MRP.
RM
1
1.1
1.2
1.1 1.2
1.1
1.2
2
1.11.2
1.11.2
1.1 1.2
1.9
SRM 1
SRM 2
1.1
1.2
1.9
1.1
1.2