Quick Reference to "C" and "E" CALIBRATION
031-300-190-169 REVISION B 01/06/04 190169_B
7
2.5 List of addresses used for AccuCal
This is a listing of the data EEPROM addresses that can be changed during the AccuCal calibration.
There are many other addresses that can be changed but these are the only ones I expect to have to
change. Many of the addresses are changed automatically and do not require the user to input data.
They are provided in the case that the user wishes to see the values that are input automatically.
2.6 DGA Function “I”
1.7 Crane Serial Number Set in automatic procedure
7.1.3 Length zero value Set in automatic procedure
7.1.4 Length end value Set in automatic procedure
7.2.3 Piston pressure zero value Set in automatic procedure
7.3.3 Rod pressure zero value Set in automatic procedure
7.8.3 Angle zero degree value Set in automatic procedure
2.7 DGB Function “J”
3.1.5 Surface relation Set automatically or manually
3.1.6 Tare Overall adjustment Set manually
3.1.7 Hook block Overall adj. Set automatically or manually
6.20 Correction length 1 Set in automatic procedure
6.21 Correction length 2 Set in automatic procedure
6.22 Correction length 3 Set in automatic procedure
6.23 Correction length 4 Set in automatic procedure
10.1 Main boom angle 1 Set in automatic procedure
10.2 Main boom angle 2 Set in automatic procedure
10.3 Main boom angle 3 Set in automatic procedure
10.4 Correction angle 1 Set in automatic procedure
10.24 Correction angle 2 Set in automatic procedure
10.25 Correction angle 3 Set in automatic procedure

Other manuals for Hirschmann PAT DS 85/0002