Quick Reference to "C" and "E" CALIBRATION
031-300-190-169 REVISION B 01/06/04 190169_B
5
2.3 Function X: Cutoff test
User Input
Hand Terminal Display
PRESS "X" Enter measured
radius or "ENTER"
Enter measured radius, Press
"ENTER“
RAT LOAD = XXXX
ACT LOAD = XXXX
Enter actual load. Press
ENTER
RAT R/A = XXXX
CUTOFF = XXXX
The cutoff percent will be shown
on the hand terminal. Record
this on the test sheet.
2.4 Procedure for load correction
2.4.1 Mainboom - Function C
Following the initial setup and Q function, the load and radius should be correct. If the hook block
needs to be adjusted use the following procedure:
NOTE: Adjustment of radius display empty and empty tackle display is possible for any boom length
1) Use the “C” function to correct from high to low angle. Do not change the radius during the
“C” function.
2) Proceed with cutoff test.
User Inputs Hand Terminal Display Remarks
PRESS "C“ Enter measured
radius or CR:
PRESS "ENTER" Enter tackle or CR
tackle: XX:
PRESS "ENTER" A=MB down, CR=End,
B=adj. On the fly
dynamic adjustment
Ö
: The empty tackle weight is corrected
dynamically for all correction positions of the
present length.
PRESS "A“ PRESS "C" prior to stop
Luff down boom, the dynamic adjustment will
be completed automatically upon reaching the
last correction position. It may happen that the
last angle is not attainable. In such cases do
not exceed load chart.
Enter measured radius or
CR:
Do not adjust the radius
PRESS "ENTER" Function "C" finished PRESS
"K"
PRESS "K"