Calibration Manual DS85
031-300-190-169 REVISION B 01/06/04 190169_B
4
2.1 Main Boom with Hook Block
User Inputs
Hand Terminal Display
Remarks
OM= XXXX,LS= XX.XX
inside LS, MB-V= X
PRESS "J" B NR. (last address used)
Enter 3.1.7 3.1.7 = XXX PRESS "K" to transmit data
Change this value until load display
is correct
Note: Only a +/- 100 is allowed
PRESS "K" If Surface Relation changes are
required.
Note: This should not need
changing
PRESS "J" 3.1.5 = XXX Change this value until static to
dynamic load display is correct
using various RPM's and lever
control.
Note: Only a +/- 100 is allowed
2.2 Main Boom with Load
User Inputs
Hand Terminal Display
Remarks
OM= XXXX,LS= XX.XX
inside LS, MB-V= X
Perform cutoff test with a light load
NO
Radius changes should be
required.
If weight changes are required
PRESS "J" B NR. (last address used)
Enter 3.1.6 3.1.6 = XXX PRESS "K" to transmit data
Change this value until load display
is correct
Note: Only a +/- 100 is allowed
PRESS "K" If Surface Relation changes are
required.
Note: This should not need
changing
PRESS "J" 3.1.5 = XXX Change this value until static to
dynamic load display is correct
using various RPM's and lever
control.
Note: Only a +/- 100 is allowed