6-6 Filter unit
WARNING
Before checking or replacing the filter unit, turn off, unplug and cool down the projector.
• To keep inside ventilation normal, check and replace the fi lter unit periodically.
• Use only the manufacturer specifi ed type of the fi lter unit.
NOTICE : Be sure to reset the FILTER TIME only when you have replaced the fi lter unit.
NOTE
The value shown on the EASY menu as the FILTER TIME is the use time that is counted since
the last time the FILTER TIME was reset. Refer to the value for proper maintenance.
You can utilise the message function which is set up by the item FILTER TIME of the OPTION
menu to notify you when to replace the lamp.
To keep inside ventilation normal, keep a spare and replace the filter unit periodically, although frequent
replacement is not needed for this product. To prepare the spare, contact your dealer ask and for the following
type number.
Type number of the optional fi lter unit: MU06351
Carry out the following the steps to replace the filter unit.
(1) Turn on the projector.
(2) To display the EASY MENU, press the MENU button
(on the control panel or the remote control). On the
ADVANCED MENU, select the “EASY MENU” using the
Ÿ/ź cursor buttons in the left column, then press the Ź
cursor button.
(3) To display the FILTER TIME dialog, select the “FILTER
TIME” using the Ÿ/ź cursor buttons then press the Ź
cursor button.
(4) Use the Ź cursor button according to the dialog,
Selecting “OK” resets the FILTER TIME value.
Filter cover
Filter unit knobs
Intake vents
Filter cover knobs
1.Make sure that the projector is unplugged and cooled down.
2.Use a vacuum cleaner on and around the fi lter cover.
3.Pick and pull up the fi lter cover knobs to take it off.
4.Pinch and pull out the fi lter unit knob to take it off.
5.Use a vacuum cleaner on and around the intake vents of
the projector.
6.Set the new fi lter unit into the place.
7.Place the filter cover back into the place.
8.Reset the FILTER TIME value.