CP-WX11000 ( P6WX )
3. Assembling and Disassembling the power unit block.
a. Assembling and Disassembling the ballast.
ATTENTION
Note the Heatsinks have the Sharp edge, at the time you connect/disconnect CNPFC.
Assembly
Disassembly
Confirm that ballast is locked by
locking spacer completely.
CNPFC
Release purse lock before you disconnect CNPFC.
A
B
C
Never loosens A, B or C.
Assemble in following procedure if
you have loosened screws A, B or C.
(1) Tighten screw A firmly.
(2) Tighten screws B and C lightly.
(3) Attach ballast board with 3 screws firmly.
(4) Tighten screws B and C firmly.
Make sure that three pairs
of screws (six screws) are
tightened firmly.
Make sure that black
sheet is not pinched
after you tighten screws.