EasyManua.ls Logo

Hitachi DK23DA-20F - Page 68

Hitachi DK23DA-20F
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K6602705
Rev.3
08.20.01
- 68 -
Error data structure
The error data structure contains the error description of the command for which an error was reported
as described in following.
Table 6.15 Error data structure
Byte Descriptions
n Reserved
n+1 Content of the Error register after command completion occurred.
n+2 Content of the Sector Count register after command completion occurred.
n+3 Content of the Sector Number register after command completion occurred.
n+4 Content of the Cylinder Low register after command completion occurred.
n+5 Content of the Cylinder High register after command completion occurred.
n+6 Content of the Device/Head register after command completion occurred.
n+7 Content written to the Status register after command completion occurred.
n+8 ~ n+25 Extended error information (Vendor Specific)
n+27 State
This contains a value indicating the state of the device when command was written
to the Command register or the reset occurred as described below.
01h: Sleep
02h: Standby
03h: Active/Idle with BSY cleared to zero
04h: Executing SMART off-line or self-test
n+28 ~ n+29 Life timestamp
This contains the power-on lifetime of the device in hours when command
completion occurred.

Table of Contents

Related product manuals