EasyManua.ls Logo

Hitachi DK23DA-20F - Page 7

Hitachi DK23DA-20F
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K6602705
Rev.3
08.20.01
- 7 -
6.3.2 Command --------------------------- 35
6.3.2.1 Command Summary --------------------------- 35
6.3.2.2 Command BSY Timing --------------------------- 36
6.3.2.3 PIO Data In Commands --------------------------- 37
6.3.2.3.1 Identify Device [ECh] --------------------------- 38
6.3.2.3.2 Read Buffer [E4h] --------------------------- 45
6.3.2.3.3 Read Sectors [20h, 21h] --------------------------- 45
6.3.2.3.4 Read Long [22h, 23h] --------------------------- 45
6.3.2.3.5 Read Multiple [C4h] --------------------------- 45
6.3.2.4 PIO Data Out Commands --------------------------- 46
6.3.2.4.1 Write Buffer [E8h] --------------------------- 46
6.3.2.4.2 Write Sectors [30h, 31h] --------------------------- 46
6.3.2.4.3 Write Long [32h, 33h] --------------------------- 46
6.3.2.4.4 Write Multiple [C5h] --------------------------- 46
6.3.2.4.5 Format Track [50h] --------------------------- 47
6.3.2.5 Non-Data Commands --------------------------- 47
6.3.2.5.1 Initialize Device Parameters [91h] --------------------------- 47
6.3.2.5.2. Read Verify [40h, 41h] --------------------------- 48
6.3.2.5.3 Recalibrate [1Xh] --------------------------- 48
6.3.2.5.4 Seek [7Xh] --------------------------- 48
6.3.2.5.5 Set Features [EFh] --------------------------- 48
6.3.2.5.6 Set Multiple Mode [C6h] --------------------------- 49
6.3.2.5.7 Execute Device Diagnostic [90h] --------------------------- 49
6.3.2.5.8 Flush Cache [E7h] --------------------------- 50
6.3.2.6 Power Commands --------------------------- 51
6.3.2.6.1 Power Management --------------------------- 51
6.3.2.6.2 Advanced Power Management --------------------------- 52
6.3.2.6.3 Check Power Mode [98h, E5h] --------------------------- 53
6.3.2.6.4 Idle [97h, E3h] --------------------------- 54
6.3.2.6.5 Idle Immediate [95h, E1h] --------------------------- 54
6.3.2.6.6 Sleep [99h, E6h] --------------------------- 54
6.3.2.6.7 Standby [96h, E2h] --------------------------- 54
6.3.2.6.8 Standby Immediate [94h, E0h] --------------------------- 54
6.3.2.7 DMA Data In/Out Commands --------------------------- 55
6.3.2.7.1 Read DMA [C8h, C9h] --------------------------- 55
6.3.2.7.2 Write DMA [CAh, CBh] --------------------------- 55
6.3.2.8 SMART Feature --------------------------- 56
6.3.2.8.1 Attribute Parameters --------------------------- 56
6.2.7.8.2 SMART Device Error Log Reporting --------------------------- 57
6.2.7.8.3 SMART Operation with Management Modes --------------------------- 57
6.3.2.8.4 SMART Function Default Setting --------------------------- 57
6.3.2.8.5 SMART Enable Operations [B0h, Sub D8h] --------------------------- 57
6.3.2.8.6 SMART Disable Operations [B0h, Sub D9h] --------------------------- 58
6.3.2.8.7 SMART Return Status [B0h, Sub DAh] --------------------------- 59
6.3.2.8.8 SMART Enable/Disable Attribute AUTOSAVE [B0h, Sub D2h] ------------------ 59
6.3.2.8.9 SMART Save Attribute Values [B0h, Sub D3h] ----------------------------- 60
6.3.2.8.10 SMART Enable/Disable Automatic Off-line [B0h, Sub DBh] -------------------- 61
6.3.2.8.11 SMART Execute Off-line Immediate [B0h, Sub D4h] --------------------------- 62

Table of Contents

Related product manuals