Item Specification
(bytes)
Maximum number of hosts via FC switch 255
Maximum number of hosts via network
switch
255
Battery life
Storage system intake temperature CBSS
Up to 75.2º F (24º C) 5 years
Up to 86º F (30º C) 5 years
Up to 93.2º (34º C) 4 years
Up to 104º (40º C) 3 years
RAID specications
Item Specification
RAID level
*
Flash drive mounted: 1/5/6
RAID conguration RAID1: 2D+2D, 4D+4D
RAID5: 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID6: 6D+2P, 12D+2P, 14D+2P
Maximum number of parity groups 64
Maximum volume size 3 TB (when using the LDEVs of other
Storage Systems: 4TB)
Maximum volumes/host groups and iSCSI
targets
2048
Maximum volumes/parity groups 2048
*
A storage system congured with RAID6, RAID 5, or RAID 1 provides redundancy and
enhances data reliability. However, there is still a possibility of losing data caused by
unforeseeable hardware or software failure. Users should always follow recommended
best practices and back up all data.
VSP F350 mechanical specications
Appendix B: System specications
Hitachi Virtual Storage Platform F350, F370 Hardware Reference Guide 48