The warning indication disappears within six hours. Even when the warning is
shown, normal operation is assured in Write-Through. Read and write
performance is lowered because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery
can become overcharged and sustain unrecoverable damage. To avoid this
situation, charge the battery more than 3 hours every six months.
Insulation performance
Item
Specification
Insulation withstand voltage AC 1,500 V (100 mA, 1 min)
Insulation resistance DC 500 V, 10 M Ω or more
74 Mechanical specifications for VSP G400, G600