L2002 Inverter
Appendix B
B–25
The table below lists the holding registers for the “F” Group Main Profile Parameters.
Note 1: When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored.
Holding Registers, “F” Group Main Profile Parameters
Func.
Code
Name R/W Description
Network Data
Register
Range Res.
hex dec.
F002
(high)
Acceleration (1) time
setting *1
R/W Standard default acceleration,
range is 0.01 to 3000 sec.
1014h 04116 1 to
300000
0.01
sec
F002
(low)
R/W 1015h 04117
F202
(high)
Acceleration (1) time
setting, 2nd motor *1
R/W Standard default acceleration,
2nd motor,
range is 0.01 to 3000 sec.
1501h 05377 1 to
300000
0.01
sec
F202
(low)
R/W 1502h 05378
F003
(high)
Deceleration (1) time
setting *1
R/W Standard default deceleration,
range is
0.01 to 3000 sec.
1016h 04118 1 to
300000
0.01
sec
F003
(low)
R/W 1017h 04119
F203
(high)
Deceleration (1) time
setting, 2nd motor *1
R/W Standard default deceleration,
2nd motor,
range is 0.01 to 3000 sec.
1503h 05379 1 to
300000
0.01
sec
F203
(low)
R/W 1504h 05380
F004 Keypad Run key routing R/W Two options; select codes:
00 ...Forward
01 ...Reverse
1018h 04120 0, 1

Table of Contents