L2002 Inverter
Appendix B
B–43
The following table lists the holding registers for the “H” Group Motor Constants.
“H” Group Motor Constants
Func.
Code
Name R/W Description
Network Data
Register
Range Res.
hex dec.
H003 Motor capacity R/W Thirteen selections:
0 .....0.20 kW
1 .....0.37 kW
2 .....0.40 kW
3 .....0.55 kW
4 .....0.75 kW
5 .....1.10 kW
6 .....1.50 kW
7 .....2.2 kW
8 .....3.0 kW
9 .....3.7 kW
10 ...4.0 kW
11 ...5.5 kW
12 ...7.5 kW
1165h 04453 0 to 12
H203 Motor capacity, 2nd
setting
R/W 1540h 05440 0 to 12
H004 Motor poles setting R/W Four selections:
2 / 4 / 6 / 8
1166h 04454 2, 4, 6,
8
1 pole
H204 Motor poles setting, 2nd
motor
R/W 1541h 05441 2, 4, 6,
8
1 pole
H006 Motor stabilization
constant
R/W Motor constant (factory set),
range is 0 to 255
1168h 04456 0 to 255 1
H206 Motor stabilization
constant, 2nd motor
R/W 1543h 05443 0 to 255 1