36
Note: Set frequency (speed) values are not permitted to be inside
the jump frequency ranges, if defined. When a frequency ref-
erence value from a real-time source (such as keypad potenti-
ometer or analog input) are inside a jump frequency range, the actual
speed is automatically forced to equal the lowest point of the jump range.
085 285
F001, A020 / A220 >f-x,
<f+x
A063 ± A064
A065 ± A066
A067 ± A068
(see note below)
086
A021 to A035 >f-x,
<f+x
091 291
A061 / A261 > B112
092 292
A062 / A262 >
095 295
F001, A020 / A220 >
096
A021 to A035 >
110
B100, B102, B104,
B106, B108, B110
>
B102, B104, B106,
B108, B110
<B100
B100 > B102
B104, B106, B108,
B110
<
B100, B102 > B104
B106, B108, B110 <
B100, B102, B104 > B106
B108, B110 <
B100, B102, B104,
B106
>B108
B110 <
B100, B102, B104,
B106, B108
>B110
120
B017, B019 < B015
B015 > B017
B019 <
B015, B017 > B019
Prg Error Code
Function code of
parameter out of
bounds
Boundary defined by...
<, > Base parameter

Other manuals for Hitachi L300P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi L300P Series and is the answer not in the manual?

Hitachi L300P Series Specifications

General IconGeneral
BrandHitachi
ModelL300P Series
CategoryInverter
LanguageEnglish

Related product manuals