2
30 40 –300LFU2 1/0 6.5 8.8
37 50 –370LFU2 1/0 || 1/0 AWG 6.5 8.8
45 60 –450LFU2 1/0 || 1/0 AWG 10.1 13.7
55 75 –550LFU2 2/0 || 2/0 AWG 10.1 13.7
75 100 –750LFU2 3/0 || 3/0 AWG 10.1 13.7
400V Models
Motor output
Inverter Model
Wire Size
(AWG)
Torque
kW HP ft-lbs (N-m)
1.5 2 –015HFU2/E2 20 1.1 1.5
2.2 3 –022HFU2/E2 18 1.1 1.5
4.0 5 –037HFU2/E2 16 1.1 1.5
5.5 7 1/2 –055HFU2/E2 14 1.1 1.5
7.5 10 –075HFU2/E2 12 1.8 2.5
11 15 –110HFU2/E2 8 3.6 4.9
15 20 –150HFU2/E2 6 3.6 4.9
18.5 25 –185HFU2/E2 6 3.6 4.9
22 30 –220HFU2/E2 4 3.6 4.9
30 40 –300HFU2/E2 3 3.6 4.9
37 50 –370HFU2/E2 1 3.6 4.9
45 60 –450HFU2/E2 1 6.5 8.8
55 75 –550HFU2/E2 1/0 AWG 6.5 8.8
75 100 –750HFU2/E2 1/0 || 1/0 AWG 6.5 8.8
90 125 –900HFU2/E2 3/0 (1/0 || 1/0
AWG)
10.1 13.7
110 150 –1100HFU2/E2 2/0 || 2/0 AWG 10.1 13.7
132 175 –1320HFU2/E2 2/0 || 2/0 AWG 10.1 13.7
200V Models
Motor output
Inverter Model
Wire Size
(AWG)
Torque
kW HP ft-lbs (N-m)