EasyManua.ls Logo

Hitachi RAS-25CNH1 - Power Module Checking Procedure; Power Module Check Caution

Hitachi RAS-25CNH1
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 111 –
How to check Power module
Checking power module using tester
Set tester to resistance range(x100).
If indicator does not swing in the following conductivity check, the power module is normal.
(In case of digital tester, since built-in battery is set in reverse direction, + and
_
terminals are reversed.)
If inner circuit of power module is disconnected (open), the indicator of tester will not swing and this may assumed as
normal. In this case, if indicator swings when + and
_
terminals are connected in reverse of diagram below, it is
normal. Furthermore, compare how indicator swings at U, V and W phases. If indicator swings the same way at each
point, it is normal.