5 Optional functions
Optional functions through Remote control
SMGB0137 rev.0 - 05/2021
138
P1 – Setting temperature in 0.5 ºC steps
This function is used to dene whether setting temperature is adjusted in 0.5 ºC steps (when set to “00”) or in 1 ºC steps
(when set to “01”).
This setting also determines whether the resolution of temperature dierential of the thermistor is 0.5 ºC (when set to
“00”) or 1 ºC (when set to “01”) enabling more precise setting control.
.5
Simplied scheme of the control system (for illustrative purposes only, as the control system also manages other
parameters):
24.0 24.1 24.2 24.3 24.4 24.5 24.6 24.7 24.8
24.9 25.0 25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8 25.9
24.0 24.1 24.2 24.3 24.4 24.5 24.6 24.7 24.8
24.9 25.0 25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8 25.9
25.0
25.0
24.5 25.5
Setting
Setting
Setting
Setting
control range control range
control range
control range
Temperature (P1=01)
Temperature (P1=00)
P2 – Not used
P3 – Temperature sensor displayed
This function is used to select the thermistor whose temperature is shown.
P4 – Display of sensor temperature
This function is used to display the temperature of the sensor selected with P3.
A/C
MODE SPEED LOUV. TEMP
COOL
Meeting Room
MODE Adj.LOUV.
P5 – Display of setting temperature when operation mode is Fan
This function is used to hide the display of setting temperature during operation in fan mode.
A/C
MODE SPEED LOUV. TEMP
COOL
Meeting Room
MODE Adj.LOUV.
P5=00: Show
A/C
MODE SPEED LOUV. TEMP
COOL
Meeting Room
MODE Adj.LOUV.
FAN
A/C
MODE SPEED LOUV. TEMP
COOL
Meeting Room
MODE Adj.LOUV.
FAN
P5=01: Hide
P6 – Operation of the ECO button
The Operation of ECO button is disabled when P6 is set to 01.
P7 – Prohibition of menu screen transition
This function is used to prohibit the access to the menu screens. The text “Display disabled” appears on screen instead.