Display when warning or fault was generated 9-4
No. Message Meaning of message Remedy
16
No Ink Drop
Charge
The ink drops are not electrically charged.
Check if the ink stream is at
about the center of the gutter.
Clean the gutter, deflection
electrode, and its
surroundings.
Adjust the excitation V-ref. to
make sure that the ink drops
are well made.
( Technical manual 6.11).
Check the ink pressure.
( Technical manual 6.9).
17
Ink Heating Unit
Temperature
Sensor Fault
The ink heating section is faulty.
Contact your nearest local
distributor.
18 F memory Fault C The controller section hardware is faulty.
Contact your nearest local
distributor.
19
F memory Fault
118
The engine section hardware is faulty.
Contact your nearest local
distributor.
20 F memory Fault M The engine section hardware is faulty.
Contact your nearest local
distributor.
22
Internal
Communication
Error S
Data processing within the engine section
is faulty.
Turn the power OFF and then
back ON.
24
Ink Heating
Unit Over Current
An overcurrent flowed to the heating unit.
Contact your nearest local
distributor.
25
Ambient
Temperature
Sensor Fault
There is an open circuit in the ambient
temperature sensing element.
Contact your nearest local
distributor.
26 Cooling Fan Fault Cooling fan is defective.
Contact your nearest local
distributor.
30 F memory Fault S The engine section hardware is faulty.
Contact your nearest local
distributor.
31 Pump Motor Fault Pump motor is faulty.
Contact your nearest local
distributor.
32
Viscometer Ink
Temperature
Sensor Fault
Fault in ink temperature detected by
viscometer occurred.
Contact your nearest local
distributor.
34
Ink Heating Unit
Temperature Low
The ink heating section is faulty.
Contact your nearest local
distributor.
35 Mode-key fault A fault was generated in the hardware.
Contact your nearest local
distributor.
37 Language key fault A fault was generated in the hardware.
Contact your nearest local
distributor.