Model name
SH1-*****-H
00041
00054
00083
00126
00175
00250
00310
00400
00470
00620
00770
00930
01160
01470
01760
02130
02520
03160
ND standard capacity
SH1-***/****H
007
015
022
037
055
075
110
150
185
220
300
370
450
550
750
900
1100
1320
Applicable
Motor ca-
pacity(kW)
(4poles)
VLD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
LD
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
ND
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Output
Rated
output
current
(A)
VLD
4.1
5.4
8.3
12.6
17.5
25.0
31.0
40.0
47.0
62.0
77.0
93.0
116
147
176
213
252
316
LD
3.1
4.8
6.7
11.1
16.0
22.0
29.0
37.0
43.0
57.0
70.0
85.0
105
135
160
195
230
290
ND
2.5
4.0
5.5
9.2
14.8
19.0
25.0
32.0
39.0
48.0
61.0
75.0
91.0
112
150
180
217
260
Overload
current
rating
VLD
110% 60sec / 120% 3sec
LD
120% 60sec / 150% 3sec
ND
150% 60sec / 200% 3sec
Rated output voltage
Three-phase(3 wire)380 to 460V (Corresponding to the incoming voltage)
Rated
capa-
city
(kVA)
400V
VLD
2.8
3.7
5.8
8.7
12.1
17.3
21.5
27.7
32.6
43.0
53.3
64.4
80.4
101.8
121.9
147.6
174.6
218.9
LD
2.1
3.3
4.6
7.7
11.1
15.2
20.1
25.6
29.8
39.5
48.5
58.9
72.7
93.5
110.9
135.1
159.3
200.9
ND
1.7
2.8
3.8
6.4
10.3
13.2
17.3
22.2
27.0
33.3
42.3
52.0
63.0
77.6
103.9
124.7
150.3
180.1
460V
VLD
3.6
4.7
7.2
10.9
15.2
21.7
26.8
34.6
40.7
53.7
66.7
80.5
100.5
127.3
152.4
184.5
218.2
273.7
LD
2.7
4.2
5.8
9.6
13.9
19.1
25.1
32.0
37.2
49.4
60.6
73.6
90.9
116.9
138.6
168.9
199.2
251.1
ND
2.2
3.5
4.8
8.0
12.8
16.5
21.7
27.7
33.8
41.6
52.8
65.0
78.8
97.0
129.9
155.9
187.9
225.2
Input
Rated input
current
(A)*1)
VLD
4.9
6.4
9.9
15.0
20.8
29.8
36.9
47.6
56.0
73.8
91.7
110.7
138.1
175.0
209.5
253.6
300.0
376.2
LD
3.7
5.7
8.0
13.2
19.0
26.2
34.5
44.0
51.2
67.9
83.3
101.2
125.0
160.7
190.5
232.1
273.8
345.2
ND
3.0
4.8
6.5
11.0
17.6
22.6
29.8
38.1
46.4
57.1
72.6
89.3
108.3
133.3
178.6
214.3
258.3
309.5
Rated input AC voltage
*2)
Control power supply: Single-phase supply 380 to 460V ( Permissible AC voltage 323 to 506V) ,
50Hz(allowable variation range: 47.5 to 52.5Hz)/60Hz (allowable variation range:57 to 63Hz)
Main circuit power supply: Three-phase(3 wire) 380 to 460V ( Permissible AC voltage 323 to 506),
50Hz(allowable variation range: 47.5 to 52.5Hz)/60Hz(allowable variation range: 57 to 63Hz)
Power
supply
capacity
(kVA) *3)*8)
VLD
3.7
4.9
7.5
11.4
15.9
22.7
28.1
36.3
42.6
56.3
69.9
84.4
105.2
133.4
159.7
193.2
228.6
286.7
LD
2.8
4.4
6.1
10.1
14.5
20.0
26.3
33.6
39.0
51.7
63.5
77.1
95.3
122.5
145.2
176.9
208.7
263.1
ND
2.3
3.6
5.0
8.3
13.4
17.2
22.7
29.0
35.4
43.5
55.3
68.0
82.6
101.6
136.1
163.3
196.9
235.9
Carrier
frequency
variation *4)
VLD
0.5 to 10.0kHz
0.5 to 8.0kHz
LD
0.5 to 12.0kHz
0.5 to 8.0kHz
ND
0.5 to 16.0kHz
0.5 to 10.0kHz
Starting torque *5)
200%/0.3Hz
180%/0.3Hz
Braking
Regenerative
Internal BRD circuit (external discharge resistor value)
*7)
Ext. regen. braking unit
Minimum resistance
value(Ω)
100
100
100
70
70
35
35
24
24
20
15
15
10
10
-
Dimensions*
6)
H(height)(mm)
255
255
255
255
260
260
260
390
390
390
540
550
550
550
700
700
740
740
W(width)(mm)
150
150
150
150
210
210
210
245
245
245
300
390
390
390
390
390
480
480
D(Depth)(mm)
140
140
140
140
170
170
170
190
190
190
195
250
250
250
270
270
270
270
Protective structure
IP20 – UL Open Type
Aprox.weight (kg)
3
3
3
3
6
6
6
8.5
8.5
8.5
22
31
31
31
41
41
53
53
*1) The rated input current is the value when the drive is operated in the rated output current. The value of the impedance at the supply side changes
due to the wiring, breaker, input reactor, etc.
*2) Make sure the following for Low Voltage Directive (LVD) compliant.
- Pollution degree 2, - Overvoltage category 3 (for 380 to 460Vac Input supply), - Overvoltage category 2 (for over 460Vac Input supply)
*3) The power supply capacity is the value of the rated output current at 440V. The value of the impedance at the supply side changes due to the wiring,
breaker, input reactor, etc.
*4) The setting range of carrier frequency [bb101] / [bb201] is limited according to the [Ub-03] setting(load type selection).
It is recommended to set the carrier frequency settings [bb101]/[bb201] equal or greater than the (maximum output frequency x 10)Hz.
For induction motor IM, it is recommended to set the carrier frequency to 2 kHz or more except V/f control. For synchronous motor
(SM)/Permanent magnet motor (PMM), it is recommended to set the carrier frequency to 8 kHz or more.
*5) The value is specified for the Hitachi standard motor controlled by the sensorless vector control when ND rating.
Torque characteristics may vary by the control system and the use of the motor.
*6) The key height of keypad is excluded from dimensions. When an option is connected, the depth is increased. Refer to the each optional Guide.
*7) Usually an external regenerative braking unit is required. However, with an optional built –in chopper braking circuit and external discharge resistor
can eliminate a external regenerative unit. The built-in chopper braking circuit is offered by order. In order to purchase, contact the nearest sales
office.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi SH1 Series and is the answer not in the manual?

Hitachi SH1 Series Specifications

General IconGeneral
BrandHitachi
ModelSH1 Series
CategoryInverter
LanguageEnglish

Related product manuals