■Analog input/output 
(Wiring example) 
 
 
 
 
 
 
 
 
 
 
■External thermistor 
(Wiring example) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  When variable resistor is connected on H-Ai1-L terminal, voltage 
input is given to inverter, Sw1 for analog input 1 (Ai1) is to be set 
on "voltage" side therefore. 
•  If a frequency meter connected in left example is current type (4 
to 20mA), set SW3 for analog output 1 (Ao1) as current output. 
NOTE) Refer to section 3.9 to 3.11 for adjustment example. 
 
 
 
 
 
 
 
 
•  Twist the cables connected from a thermistor to the TH terminal 
only between TH+ and TH-, and separate the twisted cables from 
other cables. 
•  Since very low current flows through the cables connected to the 
thermistor, separate the cables from those (power line cables) 
connected to the main circuit. 
•  The length of the cables connected to the thermistor must be 20 m 
or less. 
Voltage/current switchable analog input/output terminal
 
Common for 
analog power 
supply 
Common terminals for analog input terminals (Ai1,Ai2,Ai3) 
and analog output terminals (Ao1,Ao2). Two L terminals are 
available. 
Speed setting 
power supply 
10VDC power supply. Used for voltage input with analog 
input terminals (Ai1,Ai2,Ai3) using a variable resister. 
Max. allowable input current 20mA 
Analog input 
terminal 1 
(Voltage/current 
selector SW1) 
Either Ai1 or Ai2 can be used by switching the selector 
switch to DC0 to 10V voltage input or 0- to 20mA current 
input. Used as speed input and feedback input. 
For voltage input: 
•  Input impedance Approx.10kΩ 
•  Allowable input voltage -0.3VDC   
to 12VDC 
 
For current input: 
•  Input impedance Approx.100Ω 
•  Max. allowable input current 24mA 
Analog input 
terminal 2 
(Voltage/current 
selector SW2) 
DC-10 to 10V voltage input is available.   
Used as speed input and feedback input. 
Voltage input only: 
•  Input impedance Approx.10kΩ 
•  Allowable voltage input -12VDC to 
12VDC 
Analog output 
terminal 1 
(Voltage/current 
selector SW3) 
Either Ao1 or Ao2 can be used as an output for inverter 
monitoring data by switching the selector switch to DC0 to 
10V voltage output or 0 to 20mA current output. 
For voltage output: 
•  Max. allowable output current 2mA 
•  Output voltage accuracy ±10% 
(Ambient temperature: 25±10 
degrees C) 
For current input: 
•  Allowable load impedance 
250Ω or less 
•  Output current accuracy ±20% 
(Ambient temperature: 25±10 
degrees C) 
Analog output 
terminal 2 
(Voltage/current 
selector SW4) 
External 
thermistor 
input 
Connect to an external thermistor and trip the inverter if an 
abnormal temperature is detected. 
Connect the thermistor to TH+ and TH-. The impedance to detect 
temperature errors can be adjusted within the range 0Ω to 
10,000Ω. 
[Recommended thermistor properties] 
Allowable rated power: 100 mW or more 
Impedance at temperature error: 3kΩ 
DC0 to 5V 
[Input circuit] 
Common 
terminal for 
external 
thermistor 
input 
External thermistor 
terminals 
 
DC5V   
1kΩ 
 
DC5V   
1kΩ 
 
DC5V   
1kΩ 
 
DC5V   
1kΩ 
Thermistor 
 
Thermistor 
 
Thermistor 
 
Thermistor 
Control circuit terminal 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
 
Control circuit terminal section 
Potentiometer for frequency source 
(0.5kΩ to 2kΩ) 
* 1kΩ, 1W or more recommended