For  parameter  configuration 
[Ab-01] to [Ab-25] 
  Frequency scale conversion monitor [dA-06] 
Ab-01 Frequency 
conversion gain 
・The visualized “Output frequency scale conversion 
monitor[dA-06]” is equal to the “Output frequency 
monitor[dA-01]” multiplied by the “Frequency 
conversion gain[Ab-01]”. 
 
  Multi-speed command 
Ab-03 Multi-speed operation 
selection 
00(Binary(16 speeds))/ 
01(Bit(8 speeds)) 
Ab110 Multi-speed 0 setting, 
1st-motor 
Ab-11 Multi-speed 1 setting 
Ab-12 Multi-speed 2 setting 
Ab-13 Multi-speed 3 setting 
Ab-14 Multi-speed 4 setting 
Ab-15 Multi-speed 5 setting 
Ab-16 Multi-speed 6 setting 
Ab-17 Multi-speed 7 setting 
Ab-18 Multi-speed 8 setting 
Ab-19 Multi-speed 9 setting 
Ab-20 Multi-speed 10 setting 
Ab-21 Multi-speed 11 setting 
Ab-22 Multi-speed 12 setting 
Ab-23 Multi-speed 13 setting 
Ab-24 Multi-speed 14 setting 
Ab-25 Multi-speed 15 setting 
*1) The actual setting range is limited to the maximum frequency setting 
([Hb105/205] [Hd105/205]). 
・For the 16 speeds selection, set [Ab-03]=00 for assigning 
the intelligent terminals 003[CF1] to 006[CF4] makes 
available the use of the speeds 0 to 15.         
 
 
[Ab210][AC-01] to [AC-02] 
・For the 8 speeds selection, set [Ab-03]=01 assigning the 
intelligent terminals 007[SF1] to 013[SF7] makes 
available the use of the speeds 0 to 7. 
 
  2nd motor When Intelligent Input terminal 024[SET] is enabled. 
Ab210 Multi-speed 0 setting, 
2nd-motor 
 
  Input method for Accel/Decel time 
AC-01 
Acceleration/Deceleration 
time input source selection 
00(Parameter setting)/ 
01(Option 1)/ 
02(Option 2)/ 
03(Option 3)/ 
04(Function EzSQ) 
・[AC-01] changes the reference source for the Accel/Decel 
command. 
 
  Individual Accel/Decel time for Multispeed 
AC-02 
Acceleration/ 
Deceleration selection 
00(Common etting)/ 
01(Multi stage sccel/decel) 
・When [AC-02]=00, the Accel/Decel time settings 
[AC120][AC122] or [AC124][AC126] are enable. 
・2-stage Accel/Decel time function is set with parameters 
[AC115] to [AC117].   
・When [AC-02]=01, the Accel/Decel time [AC-30] to 
[AC-88] for each multispeed control (from speed 1 to 
15) are enabled. 
・Even if [AC-02]=01, while in Multspeed-0 command, 
Accel/Decel time setting [AC120] [AC122] or 
Accel/Decel time setting [AC124] [AC126] are enabled. 
・[CA-64]/[CA-66] takes precedence during the input 
terminal 020[FUP]/021[FDN] function. And [AH-78] 
takes precedence during the PID soft start function.