52
Main Profile Parameters
NOTE:. Mark in b031=10 shows the accessible parameters when b031 is set 10, high
level access.
F Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units

Output frequency setting
Standard default target frequency
that determines constant motor
speed, range is 0.0 / start
frequency to maximum frequency
(A004)
0.0
Hz

Acceleration time (1)
Standard default acceleration,
range is 0.01 to 3600 sec.
10.0
sec.

Acceleration time (1),
2
nd
motor
10.0
sec.

Deceleration time (1)
Standard default deceleration,
range is 0.01 to 3600 sec.
10.0
sec.

Deceleration time (1),
2
nd
motor
10.0
sec.

Keypad RUN key routing
Two options; select codes:
 Forward
 Reverse
00