53
Standard Functions
NOTE:. Mark “” in b031=10 shows the accessible parameters when b031 is set “10”, high
level access.
Eight options; select codes:
POT on ext. operator
Control terminal
Function F001 setting
Modbus network input
Option
Pulse train input
via EzSQ
Calculate function output
Frequency source,
2
nd
motor
Four options; select codes:
Control terminal
Run key on keypad, or
digital operator
Modbus network input
Option
Run command source,
2
nd
motor
Settable from 30 Hz to the
maximum frequency()
Base frequency,
2
nd
motor
Settable from 30 Hz to the 2
nd
maximum frequency()
Settable from the base
frequency to 400(1000)
*1
Hz
Maximum frequency,
2
nd
motor
Settable from the 2
nd
base
frequency to 400(1000)
*1
Hz
Three options; select codes:
...Select between [O] and [OI]
at [AT] (ON=OI, OFF=O)
...Select between [O] and
external POT at [AT]
(ON=POT, OFF=O)
...Select between [OI] and
external POT at [AT]
(ON=POT, OFF=OI)
[O] input active range start
frequency
The output frequency
corresponding to the analog
input range starting point,
range is 0.00 to 400.0(1000.)
*1
[O] input active range end
frequency
The output frequency
corresponding to the analog
input range ending point,
range is 0.0 to 400.0(1000.)
*1
[O] input active range start
voltage
The starting point (offset) for the
active analog input range,
range is 0. to 100.
[O] input active range end
voltage
The ending point (offset) for the
active analog input range,
range is 0. to 100.