54
A Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units

[O] input start frequency
enable
Two options; select codes:
Use offset ( value)
Use 0Hz
01

Analog input filter
Range n = 1 to 31,
1 to 30 : ×2ms filter
31: 500ms fixed filter with ±
0.1kHz hys.
8.
Spl.

EzSQ function select
Select codes:
Disable
Activate by PRG terminal
Activate always
00
-

Multi-speed operation
selection
Select codes:
...Binary operation (16 speeds
selectable with 4 terminals)
...Bit operation (8 speeds
selectable with 7 terminals)
00
-

Multi-speed freq. 0
Defines the first speed of a
multi-speed profile, range is 0.0 /
start frequency to 400(1000)
*1
Hz
 = Speed 0 (1st motor)
6.0
Hz

Multi-speed freq. 0,
2
nd
motor
Defines the first speed of a
multi-speed profile or a 2nd
motor, range is 0.0 / start
frequency to 400(1000)
*1
Hz
 = Speed 0 (2nd motor)
6.0
Hz

to

Multi-speed freq. 1 to 15
(for both motors)
Defines 15 more speeds,
range is 0.0 / start frequency to
400(1000)
*1
Hz.
=Speed 1 to =Speed15
See next
row
Hz
to 
0.0
Hz

Jog frequency
Defines limited speed for jog,
range is from start frequency to
9.99 Hz
6.00
Hz

Jog stop mode
Define how end of jog stops the
motor; six options:
Free-run stop (invalid during
run)
Controlled deceleration
(invalid during run)
DC braking to stop(invalid
during run)
Free-run stop (valid during
run)
Controlled deceleration
(valid during run)
DC braking to stop(valid
during run)
04

Torque boost select
Two options:
Manual torque boost
Automatic torque boost
00

Torque boost select, 2
nd
motor
00

Other manuals for Hitachi WJ200-001S