SAFETY PRECAUTIONS
WARNING
Wiring:
Wiring work shall be carried out by electrical experts.
Otherwise, there is a danger of electric shock, fire and/or damage of product.
Implement wiring after checking that the power supply is off.
Otherwise, there is a danger of electric shock and/or fire.
Be sure not to operate electrical equipment with wet hands.
Otherwise, there is a danger of electric shock and/or injury.
Do not damage cables caused by stress or sandwich.
Otherwise, there is a danger of electric shock.
Operating:
Please do not open the inverters case or optional case when the power supply is on and please
do not carry out the following operations when the power supply is on.
(1) Please do not touch the inside (ex. terminal parts).
(2) Please do not check the internal signal.
(3) Please do not put on or take off the internal wiring and connector.
Otherwise, there is a danger of electric shock and/or fire.
Do not touch the conductive parts such as the internal PCB, terminals or connector while power
is being supplied.
Otherwise, there is a danger of electric shock.
Be sure not to remove this product while inverter is powered ON.
Otherwise, there is a danger of electric shock and/or fire.
Maintenance, Inspection and Part Replacement:
Wait at least 10 minutes after turning off the input power supply before performing maintenance
and inspection.
(Confirm that charge lamp on the inverter is off, check the direct current voltage between P-N
terminals and confirm it is less than 45V)
Otherwise, there is a danger of electric shock.
Make sure that only qualified persons perform maintenance, inspection, and part replacement.
Before starting the work, remove metallic objects from your person (wristwatch, bracelet, etc.). Be
sure to use tools protected with insulation.
Otherwise, there is a danger of electric shock and/or injury.
Please do not carry out insulation resistance (megger) and voltage proof test.
Otherwise, there is a danger of electric shock and/or a possibility that the product will get
damaged.
NOTE:
Never disassemble / repair / modify the unit.
Otherwise, there is a danger of electric shock and/or injury.

Other manuals for Hitachi WJ200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi WJ200 Series and is the answer not in the manual?

Hitachi WJ200 Series Specifications

General IconGeneral
SeriesWJ200
Output Frequency0.1 to 400 Hz
Control MethodV/f Control, Sensorless Vector Control
Overload Capacity150% for 60 seconds
EnclosureIP20
CommunicationRS-485 (Modbus RTU)
Input Voltage200-240V AC, 380-480V AC
Ambient Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity5 to 95% RH (non-condensing)
Cooling MethodFan cooled
Braking UnitBuilt-in
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
Analog Inputs2