Chapter 8 PROFINET Specification
53
8.15 Warning
When WJ-PN detects warning, the warning code is stored to PNU 953 and PNU 954, and ZSW1 bit 7
is changed to ON.
The specification of PNU953 is same as d090 of WJ200 / WL200.
The specification that each bit of PNU954 becomes ON is the following.
PNU 954 bit
Conditions
0
C005 09 (2CH)
1
C006 83 (HLD)
2
Any of C001 - C007 = 06 (JG)
3
The Modbus register No. that doesnt exist is assigned in P160 - P179.
4
The 32bit length Modbus register No. isnt assigned in P160 - P179
consecutively.
5
F001 (The Modbus register No. = 0x0001 (upper), 0x0002 (lower)) is assigned in
P160 - P169.
6
There are the settings of the output frequency in P160 - P169.
There can be only a setting.
7
P170 = 0 (ZSW1), but P160 0 (STW1)
8
The sequence of upper and lower of the 32bit length Modbus register No. differ
in selected telegram.
Please refer to Chapter 6 Troubleshooting and Maintenance” of the WJ200 / WL200 instruction
manual forWarning codes for the warning about PNU953.
Even if the warning about PNU954 occurs, the inverter can run.