MAINTENANCE
7-36
Replace Fuel Filter
--- every 500 hours
1. Close fuel cock (6)..
2. Loosen ring nut (3) of fuel filter (1) and remove filter
cap (4).
3. Clean filter cap (4).
4. Install new filter element (2), filter cap (4) and
retighten ring nut (3) securely.
5. Open fuel cock (6)
6. Loosen plug (5) to bleed air.
7. Tighten plug (5) when fuel flows from the plug hole.
8. Turn the key switch ON and hold for 10 to 15 seconds
to engage automatic bleeding.
9. Start the engine and check for fuel leakage