MAINTENANCE
7-43
Clean Radiator
--- every 500 hours
WARNING: Always wear safety glasses or
goggles when using compressed air [less than
0.2 MPa (2 kgf/cm
2
, 29 psi)] to clean radiator core.
IMPORTANT:
Cover air cleaner inlet opening to prevent entry
of dust and water while cleaning the radiator.
High-pressure air [less than 0.2 MPa (2 kgf/cm
2
,
29 psi)] or water can damage radiator fins.
Keep the pressure nozzle 500 mm (19.7 in) or
more away from the core face.
The radiator and the oil cooler are arranged in series.
In case dust or dirt should become stuck to the
radiator core, clean the radiator with compressed air
and/or water to maintain the cooling ability of the
cooling system.