Resetallusersetvaluestothedefaultsettingvalues.
7.6.AllResetMode
(1)Pressthevolumeknobformorethan1secondwhilein
theallresetmode.
・Thedigitaldisplay(S)willilluminate[ ].
・TheEVCwillbeepandthedigitaldisplay(L)blinks.
・"SEL"willilluminateonthedisplay.
(2)Turnthevolumeknobtoselect"YES"or"NO".When
theselectionismade,pressthevolumeknobtoset.
・Whenselecting"NO",resetisNOTdoneandthe
digitaldisplay(L)stopsblinking.
・Whenselecting"YES",allusersetvaluesare
resettodefaultsettingvalues.Followingthis
step,gobacktosection2toredotheintialsetup.
Note
・Usethismodetoresetinitialsettingsorwhenthelockcodeislostorforgotten.
−43−
Note
・Thedefaultvalueis4.50V.
(3)Thefullthrottlevoltagevaluecanalsobemanually
inputted.PressButton①andtheiconwillnow
illuminate,indicatingyouareinmanualmode.Turn
thevolumeknobtoselecttheopenvoltageandpress
thevolumeknobtoset.
・TheEVCwillbeepandthevoltagecalueisnowset.
Generallynotneeded,butthesamplingratemodeofthesteppingmotorcanbeadjusted
ifboostvalueisunstableandfluctuatingaboveandbelowthetargetboostvalue.
7.5.SamplingRateSetMode
(1)PressthevolumeknobwhileintheSamplingRateSet
Mode.
・Thedigitaldisplay(S)willilliminate[ ].
・TheEVCwillbeepandthedigitaldisplaywillblink.
・"SEL"willilluminateonthedisplay.
(2)Turnthevolumeknobtoselectthesamplingratevalue.
Afterselectionhasbeenmade,pressthevolumeknob
tosetvalue.
・Selectfrom1・2・3・4・5samplingrates.
・Thedefaultsettingissamplingrate4.