Resetallusersetvaluestothedefaultsettingvalues.
7.6.AllResetMode
(1)Pressthevolumeknobformorethan1secondwhilein
theallresetmode.
  ・Thedigitaldisplay(S)willilluminate[   ].
  ・TheEVCwillbeepandthedigitaldisplay(L)blinks.
  ・"SEL"willilluminateonthedisplay.
(2)Turnthevolumeknobtoselect"YES"or"NO".When
theselectionismade,pressthevolumeknobtoset.
  ・Whenselecting"NO",resetisNOTdoneandthe
digitaldisplay(L)stopsblinking.
  ・Whenselecting"YES",allusersetvaluesare
resettodefaultsettingvalues.Followingthis
step,gobacktosection2toredotheintialsetup.
Note
・Usethismodetoresetinitialsettingsorwhenthelockcodeislostorforgotten.
−43−
Note
・Thedefaultvalueis4.50V.
(3)Thefullthrottlevoltagevaluecanalsobemanually
inputted.PressButton①andtheiconwillnow
illuminate,indicatingyouareinmanualmode.Turn
thevolumeknobtoselecttheopenvoltageandpress
thevolumeknobtoset.
  ・TheEVCwillbeepandthevoltagecalueisnowset.
Generallynotneeded,butthesamplingratemodeofthesteppingmotorcanbeadjusted
ifboostvalueisunstableandfluctuatingaboveandbelowthetargetboostvalue.
7.5.SamplingRateSetMode
(1)PressthevolumeknobwhileintheSamplingRateSet
Mode.
  ・Thedigitaldisplay(S)willilliminate[   ].
  ・TheEVCwillbeepandthedigitaldisplaywillblink.
  ・"SEL"willilluminateonthedisplay.
(2)Turnthevolumeknobtoselectthesamplingratevalue.
Afterselectionhasbeenmade,pressthevolumeknob
tosetvalue.
  ・Selectfrom1・2・3・4・5samplingrates.
  ・Thedefaultsettingissamplingrate4.