6. Signalling during Loader Operation
When the loader is remote controlled, the operator must keep an eye on the
indications of the RCL indicator panel. Please see the RCL Instruction Manual
of the loader.
To avoid unexpected stops of the loader movements, it is important to pay
attention to the indications from the buzzer of the remote control box. A periodic
signal from the buzzer during 30 seconds indicates that the battery has to be
changed (recharged).
Move the loader into a safe position within the 30 seconds of the periodic signal
from the buzzer.
If the indicator lamp on the remote control box turns off and the loader cannot
be remote controlled, it may be due to radio interference or system errors.
Please see chapter on troubleshooting.
7. Emergency Stop during Loader Operation
If a dangerous situation occurs, where you are about to loose control of the
loader, push the stop button on the remote control box and stop the loader.
When the stop button is pushed on the remote control box, the RCL controller
registers this as an error. The RUN and FUNC diodes start flashing.
Start up the IRC-system again according to the procedure and continue loader
operation.
Please note! Every time the IRC-system is started up, always test the
functioning of the stop button. When pushing the stop button, it must not be
possible to remote control the loader.
8. Stopping the IRC-System
After loader operation, interrupt the IRC-system according to the following
procedure:
Push the stop button.
Turn the key switch into position “0”, pull out the key and keep it with you.
Stop the hydraulic pump, the power to the system is thus interrupted