EasyManua.ls Logo

Holtek BS82B12A-3 - Power-On Reset Characteristics

Holtek BS82B12A-3
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev. 1.20 24 January 23, 2015 Rev. 1.20 25 January 23, 2015
BS82B12A-3/BS82C16A-3/BS82D20A-3
Touch Key 8-Bit Flash MCU with LED/LCD Driver
BS82B12A-3/BS82C16A-3/BS82D20A-3
Touch Key 8-Bit Flash MCU with LED/LCD Driver
Touch Key RC OSC =2000kHz
Symbol Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Condition
I
KEYOSC
Only Sensor (KEY) Oscillator
Operating Current
3V
*f
SENOSC
=2000kHz, MnFILEN=0
80 160
μA
5V 160 320
3V
*f
SENOSC
=2000kHz, MnFILEN=1
120 240
μA
5V 200 400
I
REFOSC
Only Reference Oscillator
Operating Current
3V
*f
REFOSC
=2000kHz,
MnTSS=0, MnFILEN=0
80 160
μA
5V 160 320
3V
*f
REFOSC
=2000kHz,
MnTSS=0, MnFILEN=1
80 160
μA
5V 160 320
3V
*f
REFOSC
=2000kHz,
MnTSS=1, MnFILEN=0
80 160
μA
5V 160 320
3V
*f
REFOSC
=2000kHz,
MnTSS=1, MnFILEN=1
120 240
μA
5V 300 600
C
KEYOSC
Sensor (KEY) Oscillator
External Capacitance
3V
*f
SENOSC
=2000kHz
4 8 16
pF
5V 5 10 20
C
REFOSC
Reference Oscillator Internal
Capacitance
3V
*f
SENOSC
=2000kHz
4 8 16
pF
5V 5 10 20
f
KEYOSC
Sensor (KEY) Oscillator
Operating Frequency
3V
*
External Capacitance
=1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,
… 50pF
150 2000 4000
kHz
5V 150 2000 4000
f
REFYOSC
Reference Oscillator
Operating Frequency
3V
*
Internal Capacitance
=1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,
… 50pF
150 2000 4000
kHz
5V 150 2000 4000
Note:*f
SENOSC
=2000kHz:adjusttheKEYncapacitortomaketheSensorOscillatorfrequency=2000kHz.
*f
REFOSC
=2000kHz:adjusttheReferenceOscillatorinternalcapacitortomaketheReferenceOscillator
frequency=2000kHz
Power-on Reset Characteristics
Symbol Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Conditions
V
POR
V
DD
Start Voltage to eEnsure Power-on Reset 100 mV
RR
VDD
V
DD
Raising Rate to Ensure Power-on Reset 0.035 V/ms
t
POR
Minimum Time for V
DD
Stays at V
POR
to
Ensure Power-on Reset
1 ms





