EasyManua.ls Logo

HOMCOM A90-246 - Errors and Trouble Shooting

HOMCOM A90-246
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
~ 10 ~
How to add lubricant
Please adhere to the following instructions carefully.
Open the side bar on the front left of the refuelling decorative cover. Insert
the bottle into the opening to measure the size, use a pair of scissors or art
knife to cut off tip of the bottle to size. Place the bottle into the hole and
squeeze the bottle (as illustrated to refuel). Please ensure the oil bottle tip
of the thin rod is inserted correctly and securely into the fuel pipe on the
platform and then pour oil into it.
8. ERRORS AND TROUBLE SHOOTING
8.1. The electronic table displays the error message code and excludes:
FAULT CODE ISSUE SOLUTION
E1
Communication anomalies:
power-on control and electronic
table communication aabnormal.
Possible causes: electronic control and electronic table
communication is blocked, check the electronic table to the next
section of the control communication line of the connection, to
ensure that each core is fully inserted. Check if the electronic
table is connected to the controller break, replace the cable.
E2 High voltage fault Check the motor line for damage, odour, replace the motor.
E3 No motor detected Check that the motor line is connected and reconnect the motor
line. Check the motor line for damage, odor, replace the motor.
E5 Over current protection: In the
operational state, the control
continuously detects that the DC
motor current is greater than the
amount of fixed current, up to 3
seconds
Possible reasons: more than the rated load caused by excessive
current, system self-preservation, or a part of the treadmill is
stuck dead, resulting in the motor cannot turn, the load is too
heavy, the current is too large, the system self-insurance; There
is also
checking the motor for over current or burning odor,
replacing the motor, checking the controller for burning air,
replacing the controller, or checking that the supply voltage
specifications are not high or low, retest using the correct voltage
specifications.
E6 Explosion protection: abnormal
supply voltage or motor anomalies,
etc. lead to drive motor circuitry
damage.
Possible cause: Check if the supply voltage is below normal.
50%, retest with the correct voltage specifications, check the
controller for odour, replace the controller, check that the motor
line is connected, and reconnect the motor line.
E07 Safety switch not on. Put the security lock in place.