5898 Wireless DUAL TEC
®
Motion Sensor - Installation Instructions
PRELIMINARY DRAFT 5/18/09
- 1 -
O
P
E
N
/
O
U
V
E
R
T
U
R
E
/
A
P
E
R
T
U
R
A
L
O
C
A
T
I
O
N
/
E
M
P
L
A
C
E
M
E
N
T
/
L
O
C
A
L
I
Z
A
C
I
Ó
N
2
.
1
-
2
.
4
m
(
7
-
8
f
t
)
A
B
Wide Angle Lens (installed)
Wide Angle Lens (installed)
Wide Angle Lens (installed)
Animal Immune Lens (included)
Animal Immune Lens (included)
Animal Immune Lens (included)
2
1
C
O
M
P
O
N
E
N
T
S
A
N
D
S
E
T
T
I
N
G
S
/
C
O
M
P
O
N
E
N
T
S
A
N
D
S
E
T
T
I
N
G
S
/
C
O
M
P
O
N
E
N
T
S
A
N
D
S
E
T
T
I
N
G
S
C
Range Adjustment
Réglage de la portée hyper
Ajuste del rango de detección
E
C
O
N
N
E
C
T
T
H
E
B
A
T
T
E
R
I
E
S
/
C
O
N
N
E
C
T
T
H
E
B
A
T
T
E
R
I
E
S
/
C
O
N
N
E
C
T
T
H
E
B
A
T
T
E
R
I
E
S
D
M
O
U
N
T
/
I
N
S
T
A
L
L
A
T
I
O
N
/
M
O
N
T
A
J
E
R
e
a
r
T
a
m
p
e
r
B
r
e
a
k
a
w
a
y
T
a
b
s
-
B
e
s
t
if
m
o
u
n
t
e
d
t
o
a
s
t
u
d
,
s
o
lid
w
o
o
d
,
o
r
w
it
h
a
r
o
b
u
s
t
w
a
ll
a
n
c
h
o
r
.
<
F
R
-
C
A
>
R
e
a
r
T
a
m
p
e
r
B
r
e
a
k
a
w
a
y
T
a
b
s
-
B
e
s
t
if
m
o
u
n
t
e
d
t
o
a
s
t
u
d
,
s
o
lid
w
o
o
d
,
o
r
w
it
h
a
r
o
b
u
s
t
w
a
ll
a
n
c
h
o
r
.
<
S
P
-
L
A
>
R
e
a
r
T
a
m
p
e
r
B
r
e
a
k
a
w
a
y
T
a
b
s
-
B
e
s
t
if
m
o
u
n
t
e
d
t
o
a
s
t
u
d
,
s
o
lid
w
o
o
d
,
o
r
w
it
h
a
r
o
b
u
s
t
w
a
ll
a
n
c
h
o
r
.
ON
2
3 41
ON
2
3 41
PIR Sensitivity - LOW; Pulse Count 2; 
Up to 100 lb (45 kg) Animal Immunity
<FR-CA> PIR Sensitivity - LOW; Pulse Count 2; 
Up to 100 lb (45 kg) Animal Immunity
<SP-Amer> PIR Sensitivity - LOW; Pulse Count 2; 
Up to 100 lb (45 kg) Animal Immunity
PIR Sensitivity - HIGH; Pulse Count 1; 
Up to 50 lb (22.6 kg) Animal Immunity
<FR-CA> PIR Sensitivity - HIGH; Pulse Count 1; 
Up to 50 lb (22.6 kg) Animal Immunity
<SP-Amer> PIR Sensitivity - HIGH; Pulse Count 1; 
Up to 50 lb (22.6 kg) Animal Immunity
60 Hz Fluorescent Light Filter
60 Hz Fluorescent Light Filter
60 Hz Fluorescent Light Filter
50 Hz Fluorescent Light Filter
50 Hz Fluorescent Light Filter
50 Hz Fluorescent Light Filter
Alarm when < 45
o
F (7
o
C) for > 5 minutes
Alarm when < 45
o
F (7
o
C) for > 5 minutes
Alarm when < 45
o
F (7
o
C) for > 5 minutes
Alarm when > 95
o
F (35
o
C) for > 5 minutes
Alarm when > 95
o
F (35
o
C) for > 5 minutes
Alarm when > 95
o
F (35
o
C) for > 5 minutes
Microwave Walk Test Mode
Microwave Walk Test Mode
Microwave Walk Test Mode
Normal Walk Test Mode
Normal Walk Test Mode
Normal Walk Test Mode
Question and Answer IconNeed help?

Do you have a question about the Honeywell 5898 and is the answer not in the manual?

Honeywell 5898 Specifications

General IconGeneral
Field of View90°
RF Frequency345 MHz
Supervisory Interval60 minutes
Detection Range40 ft (12.2m)
Operating Temperature32°F to 120°F (0°C to 49°C)
Operating Humidity5% to 95% (non-condensing)
Battery LifeUp to 5 years
Range200 ft (open air)
CompatibilityHoneywell Wireless Alarm Systems
Battery Type3V Lithium Battery (e.g., Duracell DL123A or Panasonic CR123A)

Summary

Device Components and Settings

Installation and Testing Procedures

Pre-Mounting Checks

Perform Go/No Go tests to verify signal strength before permanent mounting.

Sensor Enrollment Process

Enroll the sensor's ID in the system during the initial walk test mode.

Normal Walk Test Mode

Optimize sensor enrollment and verify detection signals.

Microwave Walk Test

Adjust microwave range and observe LED for desired detection range.

Troubleshooting and Specifications

Trouble Indicators and Solutions

Identifies trouble conditions like self-test failures and provides resolution steps.