BENDIX/KING
KAP 140
Page 5--13
Revision 2, Dec/2002
CS:15574F02.IDU
ERR# TEXT MESSAGE(S) POSSIBLE FAILED UNIT(S)
DESCRIPTION OF ERROR
157 ECAL Bad sign input to summer KC 140
An error has occurred in the mode algorithm calculation.
158 ECAL Not enough node inputs KC 140
An error has occurred in the mode algorithm calculation.
159 ECAL Filtering out of range KC 140
An error has occurred in the mode algorithm calculation.
160 ECAL Default error KC 140
An error has occurred in the mode algorithm calculation.
161 ECAL Bad Node Record KC 140
An error has occurred in the mode algorithm calculation.
162 ECAL Bad Block Pointer KC 140
An error has occurred in the mode algorithm calculation.
163 ECAL Mode Index out of range KC 140
An error has occurred in the mode algorithm calculation.
170 Accel reasonability check failed KC 140, Unstored acceleration offset in KCM 100
The current accelerometer output was 0.8g’s greater than the previous averaged
value for the accelerometer for 1.0 seconds and the AP mode was disconnected.
Pitch axis operation will be disallowed until the excessive acceleration is
removed. This monitor runs continuously whether the AP mode is engaged or not.
This error code is logged only when the monitor fails. (This means that if
this error code has been logged and you clear the error codes and the monitor
remains failed, the KC 140 will not log the error again. The error code will
only be logged again after the monitor failure has cleared and the monitor
fails a second time.) Note: This error may be logged at power up if the acceleration
offset has not been stored in the KCM 100 Configuration Module.
175 RS232 status reg error
An error has occurred in the serial interface. There may be an intermittent
in the remote terminal interconnect or an erroneous transient occurred during
terminal powerup. Unless this error occurs after normal serial communications
have been established, it can probably be ignored.
176 RS232 receive queue full KC 140
An error has occurred in the serial interface. The receive character buffer
was filled before it could be serviced.
177 RS232 unknown interrupt KC 140
An error has occurred in the serial interface. The UAR T interrupted the processor
for unknown reasons.