ERR# TEXT MESSAGE(S) POSSIBLE FAILED UNIT(S)
DESCRIPTION OF ERROR
190 Error in Encoding Altimeter Input Altimeter, KC140
The parallel altitude information from the altimeter is not a valid Gilham
code. The altimeter may be powered off or there may be a broken wire in the
harness. The Altitude ARM mode will be disconnected if this occurs.
191 Error in remote baro input KC 140, Altimeter
The remote baro input is outside the valid operating range. The KC 140 will
revert to using its baro select knob.
192 Error in pressure sensor input KC 140
The pressure transducer signal is outside the valid operating range. ALT ARM
mode, ALT hold mode, and AP mode will be disconnected if this occurs. Pitch
Axis operation will be disallowed until the pressure transducer signal is valid
again.
193 Erroneous Altimeter Reading KC 140, Altimeter
The software detected a greater than 100 foot change between samples of the gillham
altitude.
200 SREC upload memory overrun KC 140
This is a development mode error and should not occur in production units.
There was an error in the attempt to upload a new algorithm. The upload buffer
became full before the entire file was transferred.
201 SREC upload checksum error KC 140
This is a development mode error and should not occur in production units.
There was an error in the attempt to upload a new algorithm. The upload data
does not match the checksum in the file.
202 Invalid ECAL slot KC 140
This is a development mode error and should not occur in production units.
There was an error in the attempt to upload a new algorithm. An erroneous upload
buffer number was passed to the algorithm loader.
240 Acc Mon roll clutch eng failed KC 140, KS 271C, harness wiring
An attempt to engage the roll clutch during PFT failed. No current was sensed
in the roll clutch. This error code is not present in software flavors --0103,
and --0104. Pitch Axis operation will be disallowed.
241 Acc Mon pitch clutch eng failed KC 140, KS 270C, harness wiring
An attempt to engage the pitch clutch during PFT failed. No current was sensed
in the pitch clutch. This error code is not present in software flavors --0103,
and --0104. Pitch Axis operation will be disallowed.