BENDIX/KING
KAP 140
Page 3--25
Revision 2, Dec/2002
CS:15574F02
System mode: Normal
KC 140 error log
Number of errors: 10; Current power cycle and delta time: 6, 01:02:45
# Power cycle Delta Time Error Description
--- ----------- ---------- ----- ------------------------------
1 1 00:02:03 95 roll invalid
2 1 00:05:09 91 lat cpld invalid
3 2 00:00:07 34 accel mon below lower lmt
4 3 00:00:30 39 trim mon 4 - auto failed
5 4 00:04:26 100 HDG denied
6 4 00:04:31 91 lat cpld invalid
7 4 00:05:41 112 MET fail
8 4 00:07:08 96 pitch invalid
9 5 00:08:14 111 MET runaway
10 6 00:25:37 103 REV denied
<CR> to exit
FIGURE 3--13 ERROR LOG DATA SCREEN
Pressing ‘C’ while the Error Log Menu screen is displayed will clear all errors stored in non-volatile
memory.
Pressing ‘R’ while the Error Log Menu screen is displayed will clear all errors stored in non--volatile
memory and reset the power cycle number to zero (0).
Pressing ‘F’ when the Error Log Menu screen is displayed will allow the user to capture the logged
error code data to a file. When ‘F’ is pressed, the following two lines will appear at the bottom of
the Error Log Menu screen:
Setup for file capture now.
press <CR> to dump error log, any other key to abort.
At this point, the terminal emulator program used for the RTI should be configured to receive a file.
Once this is done, the ‘ENTER’ key should be pressed to start the file transfer. Once the file
transfer is complete (new error log information will stop being scrolled on the display), the file
transfer should be terminated using the communication program. The file set up by the file transfer
configuration will then contain the error log information as text. To return to the Error Log Menu
screen, the ‘ENTER’ key should be pressed once more.