Honeywell Bendix/King KFD 840 Primary Flight Display
Emergency Operations KFD 840 PG PN 7450-0840-01
10-6 Rev C May 28, 2010
© Honeywell International Inc. Do not copy without express permission of Honeywell
DISPLAYED ERROR
DESCRIPTION
CONFIGURATION INTERNAL
CHECKSUM FAILURE
FLIGHT OK- PRESS MIDDLE
BUTTON TO CONTINUE
This message is to provide
pilot awareness that there is
a difference between the
configuration module and the
PFD data. The configuration
module data will be used.
Flight and continued flight is
permitted. It is recommended
obtaining maintenance at the
next available opportunity.
CONFIGURATION MODULE
CHECKSUM FAILURE
FLIGHT OK- PRESS MIDDLE
BUTTON TO CONTINUE
This message is to provide
pilot awareness that there is
a difference between the
configuration module and the
PFD data.
The display
information stored in the PFD
will be used. Flight and
continued flight is permitted.
It is recommended obtaining
maintenance at the next
available opportunity.
NO CONFIGURATION MODULE
FLIGHT OK- PRESS MIDDLE
BUTTON TO CONTINUE
This message is to provide
pilot awareness the
configuration module cannot
be sensed by the display
system.
The display
information stored in the PFD
will be used.
Flight and
continued flight is permitted.
It is recommended obtaining
maintenance at the next
available opportunity.
MINOR FAILURE INDICATIONS
Loss of data, no computed data or failures to non critical or
secondary display parameters will amber dash the data value field.