Technical Specifications and Dimensions
Part No.: 4417591_Rev10 Introduction Manual
CIU 888 2 - 1
CHAPTER 2 TECHNICAL SPECIFICATIONS AND DIMENSIONS
2.1 Technical Specifications - Functional (Software version R140)
General
Description Field scanning and communication interface for tank Inventory applications with
optional embedded tank inventory calculation functionality.
Application For all applications requiring accurate and reliable process and inventory data, such as
refineries, tank farms and terminals. Data is suitable for custody transfer, safe product
transfer and tank farm operation.
Intended Use Control room equipment.
Legal Metrology and Custody
Transfer
Compliant to API standards as stated by approval and certification by notified bodies as
NMi.
Functional Specification
Tank Database 80 tanks
Redundancy Hot standby and real-time synchronization.
Switchover within 10 seconds.
Supported Gauge Models All GPU enabled tank gauges (such as 811, 813, 865, 866, 854, 872, 873, 877, 894,
and 990)
Modbus Gauges Smartline level transmitter (SLG 700) via Moore HCS Modbus HART converter
TRL/2 Gauges Honeywell TRL/2 Radar gauge (990) and Rex gauge (Rex RTG)
Gauge Commands - Lock Test
- Freeze
- Alarm Test (SmartRadar)
- Unlock
- Calibrate (854, 894, 990)
- Water Dip
- Block
- Density Dip
Tank Scanning Max. 6 field ports sequential and/or parallel.
Inventory Calculations Conform API MPMS Ch. 12.1.
Tank Capacity Tables
(Strapping Tables)
Up to 5,000 straps per tank. 400,000 straps total.
Support API/ASTM Product
Calculations
- ASTM D1250-52 Table 23, 24, 53 and 54
- ASTM D1250-1980; conform Vol. X - Tables, 5, 6, 23, 24, 53, 54, 59 and 60 and 59,
60 Alternative Temperature, product groups A, B, C, D
- API MPMS Ch. 11.1 (2007; adj. to ASTM D1250-04 and IP-200) - Tables 5, 6, 23,
24, 53, 54, 59, 60 and 59, 60 Alternative Temperature, product groups A, B, C, D
- API MPMS Ch. 11.2.4 (GPA TP-27) - Tables 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60
Alternative Temperature
Product Group E - ASTM D4311-83 Table 1 and 2
- ASTM D4311-96 Table 1
- ASTM D4311-04 Table 1 and 2
Available Gauge Data - Product Level
- Product Temperature
- Vapor Pressure
- Water Level
- Spot Temperatures
- Gauge Status and Alarms
- Vapor Temperature
- Ambient Temperature
- Observed Density (Servo, HTG, HIMS)