24 75 Series Mobile Computer User Guide
Configure the Heater in the Settings App
1. Tap All apps > Settings.
2. Tap Heater under Honeywell settings.
3. Modify the heater parameters.
4. Tap Update to apply the changes.
5. Tap OK.
Configure the Heater in the EZConfig
You can also configure the heater by modifying key values in EZConfig.
1. Tap All apps > Settings > Power Tools > EZConfig.
2. Tap Menu > Generator.
Heater Cycle Time
Duration
When the heaters are activated, the computer
cycles power between the scanner window heater
and the display window heater. You can
independently adjust the cycle time for each
heater.
Note: During pre-heating, there is a small buffer
time between heater cycles when both
heaters are turned off. The length of the
buffer is not configurable.
Duration:
Scanner heater
(seconds)
DurationScanner Set the length of time (seconds) that the scanner
heater is cycled on.
Duration:
LCD heater
DurationLCD Set the length of time (seconds) that the screen
heater is cycled on.
Fast monitoring
interval
FastInterval Set sampling interval time (seconds) used once the
computer detected cold storage entry (defined by
the Heater enabled temperature.
Slow monitoring
interval
SlowInterval Set sampling interval time (seconds) used once the
computer detects cold storage exit (defined by
DeltaT).
Sample Window SampleTimes Set how many temperature samples are used to
calculate a true DeltaT event (cold storage exit).
Power on time PowerOnTime Set the length of time (minutes) that the computer
waits after the Chill timer has expired before
activating the low power pre-heat window feature.
Disable temperature DisableT Set the temperature limit (°C) that triggers turning
off the heater.
Blanking Toggles turning the heater on or off during
scanning.