® U.S. Registered Trademark EN2B-0285GE51 R0909
Copyright © 2009 Honeywell Inc.
All Rights Reserved
Excel 10
W7752D,E,F,G,J AND W7754K,L,M,P
FAN COIL UNIT CONTROLLERS
LNS PLUG-INS
HONEYWELL EXCEL 5000 OPEN SYSTEM
USER GUIDE
CONTENTS
Introduction .................................................................................................................................................................................. 1
Description of Devices ................................................................................................ 1
Products Covered ....................................................................................................... 2
Organization of Manual ............................................................................................... 2
Applicable Literature ................................................................................................... 2
Product Names ........................................................................................................... 2
Control Application...................................................................................................... 3
Control Provided ......................................................................................................... 3
Setpoints.......................................................................................................... 4
Bypass............................................................................................................. 6
LED/LCD ......................................................................................................... 6
Energy-Saving Features .................................................................................. 6
Occupancy Status............................................................................................ 7
Safety Features ............................................................................................... 8
Operating Modes ............................................................................................. 8
Construction................................................................................................................ 9
Excel 10 W7752 FCU Controllers .................................................................... 9
Excel 10 W7754 FCU Controllers .................................................................... 9
Controller Performance Specifications........................................................... 11
Configurations........................................................................................................... 12
General.......................................................................................................... 12
Fan Type ....................................................................................................... 12
Type of Heating and Cooling Equipment ....................................................... 13
Reheat Output ............................................................................................... 14
Digital Input.................................................................................................... 14
Excel 10 Wall Module Options ....................................................................... 15
Abbreviations and Definitions.................................................................................... 16
Application Steps ....................................................................................................................................................................... 17
Overview................................................................................................................... 17
Step 1. Plan the System............................................................................................ 17
Step 2. Determine Other Bus Devices Required....................................................... 17
Step 3. Lay Out Communications and Power Wiring ................................................ 18
LONWORKS Layout ......................................................................................... 18
Power Wiring ................................................................................................. 19
Step 4. Prepare Wiring Diagrams ............................................................................. 19
General Considerations ................................................................................. 19
Terminal Block Assignment and Wiring Example for the W7752 Controller... 21
Terminal Block Assignment and Wiring Example for the W7754 Controller... 22
LONWORKS Termination ................................................................................. 23
Step 5. Order Equipment .......................................................................................... 24
Step 6. Configure Controllers.................................................................................... 25
General.......................................................................................................... 25
Output............................................................................................................ 26
Input............................................................................................................... 27
Equipment Control ......................................................................................... 28
Fan ................................................................................................................ 28
Switching Levels ............................................................................................ 29
Zone Options ................................................................................................. 29
Miscellaneous ................................................................................................ 29

Table of Contents

Questions and Answers:

Honeywell Excel 10 W7752D Specifications

General IconGeneral
ModelW7752D
Input Voltage24 VAC
HousingPlastic Enclosure
Controller TypeProgrammable
ApplicationHVAC Control
Communication ProtocolLonTalk
Operating Temperature0 to 50°C

Summary

Introduction to Excel 10 FCU Controllers

Description of Excel 10 FCU Devices

Details on the various Excel 10 FCU controllers and products covered in the manual.

Products Covered by the Manual

Lists the specific Excel 10 FCU controllers and accessories covered in this guide.

Control Application Overview

Describes how the FCU controllers manage room temperature via heating/cooling equipment.

Control Provided by FCU Controllers

Details the temperature control sequence and PID algorithm capabilities.

Application Steps for Excel 10 FCU Systems

Step 1: Plan the System

Guidance on planning system requirements and estimating components.

Step 5: Order Equipment

Information on part numbers and ordering controllers and accessories.

Step 6: Configure Controllers

Details on configuring controller parameters using plug-ins.

Step 7: Troubleshooting

Guidance on diagnosing and resolving common issues.

Appendix A: LNS Tool for Fan Coil Unit Commissioning

Appendix B: Master/Slave Operation Configuration

Energy-Saving Features

Safety Features of FCU Controllers

Controller Performance Specifications

Configurations Overview

Reheat Output Configuration

Digital Input Configuration

Common Temperature Control (Master/Slave)

Prepare Wiring Diagrams

W7752 Controller Terminal Block Assignment

W7754 Controller Terminal Block Assignment

Configure Controllers - General

Output Configuration Options

Input Configuration Options

Equipment Control Configuration

Fan Configuration Options

PID Configuration

Troubleshooting FCU Controllers and Wall Modules

Alarms and Alarm Conditions

How alarm conditions are reported and managed.