Code 93 Append
This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to
the host computer. When this function is enabled, the scanner stores those Code 93 bar codes that start with a space
(excluding the start and stop symbols), and does not immediately transmit the data. The scanner stores the data in the
order in which the bar codes are read, deleting the first space from each. The scanner transmits the appended data when
it reads a Code 93 bar code that starts with a character other than a space. Default = Off.
Code 93 Code Page
Code pages define the mapping of character codes to characters. If the data received does not display with the proper
characters, it may be because the bar code being scanned was created using a code page that is different from the one the
host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were
created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from
the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
On
* Off
Code 93 Code Page

Table of Contents

Other manuals for Honeywell Genesis 7580G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Genesis 7580G and is the answer not in the manual?

Honeywell Genesis 7580G Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-70 - 70 °
Motion tolerance (cm/s)200
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesUSB, RS-232, RS-485, Keyboard wedge
Product colorBlack, Silver
Input voltage5.5 V
Power consumption (standby)0.5 W
Power consumption (typical)2 W
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth80 mm
Width83 mm
Height150 mm
Weight340 g