EasyManua.ls Logo

Honeywell XENON 1900 User Manual

Honeywell XENON 1900
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Xenon™ 1900/1910
Xenon™ 1902/1912
Granit™ 1910i/1911i
Area-Imaging Scanner
User’s Guide

Table of Contents

Other manuals for Honeywell XENON 1900

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g

Summary

Disclaimer

Product Agency Compliance - Xenon 1900/1910 USA

FCC Part 15 Subpart B Class B

Device compliance with FCC Rules Part 15 Subpart B Class B.

Canada

Industry Canada ICES-003

Class B digital apparatus compliance with Canadian ICES-003.

Europe

Waste Electrical and Electronic Equipment Information

Honeywell compliance with Directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

Germany

GS Symbol Compliance

Product marked with GS symbol indicating compliance to EN 60950-1.

Australia/NZ

C-Tick Statement

Statement indicating conformity to AS/NZS 3548 EMC requirement.

Russia

Gost-R Certificate

Certificate indicating compliance with Gost-R requirements.

International

LED Safety Statement

Scanner LEDs tested and classified as EXEMPT RISK GROUP per IEC 62471:2006.

CB Scheme

Certification to CB Scheme IEC 60950-1, Second Edition.

Laser Safety Statement

Statement on product containing a laser engine or aimer, including compliance.

Patents

Solids and Water Protection

Xenon 1900 IP41 Rating

Xenon 1900 has IP41 rating, immunity to foreign particles and dripping water.

Product Agency Compliance - Xenon 1902/1912 and CCB01-010BT Base USA

FCC Part 15 Subpart C

Device compliance with FCC Rules Part 15 Subpart C.

Canada

Industry Canada

Scanner compliance with Canadian RSS-210.

Europe

Waste Electrical and Electronic Equipment Information

Honeywell compliance with Directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

Germany

GS Symbol Compliance

Product marked with GS symbol indicating compliance to EN 60950-1.

Australia/NZ

C-Tick Statement

Statement indicating conformity to AS/NZS 3548 EMC requirement.

Brazil

Anatel Approval

Product approved by Anatel according to Resolution No. 242/2000.

China

SRRC Radio Certificate

Certificate for SRRC radio compliance.

Japan

Technical Regulations Conformity Certification

Compliance with Technical Regulations Conformity Certification of Specified Radio equipment.

Korea

Korean Agency Approval

Product meets Korean agency approval.

Mexico

NOM-019 Conformance

Conformance to NOM-019.

Cofetel Approval

Product meets Cofetel approval.

Russia

Gost-R Certificate

Certificate indicating compliance with Gost-R requirements.

Taiwan

BSMI Standard Compliance

Taiwan agency approval based on BSMI Standard CNS13438, CNS14336.

NCC Standard Compliance

Taiwan NCC standard for low power frequency electric machineries: LP0002.

International

LED Safety Statement

Scanner LEDs tested and classified as EXEMPT RISK GROUP per IEC 62471:2006.

Radio Technology

Bluetooth Class II radio technology information.

CB Scheme

Certification to CB Scheme IEC 60950-1, Second Edition.

Laser Safety Statement

Statement on product containing a laser engine or aimer, including compliance.

Product Agency Compliance - Granit 1910i USA

FCC Part 15 Subpart B Class B

Device compliance with FCC Rules Part 15 Subpart B Class B.

Canada

Industry Canada ICES-003

Class B digital apparatus compliance with Canadian ICES-003.

Canadian Regulatory Compliance

Applies Canadian ISM standard CNR-210.

Europe

Waste Electrical and Electronic Equipment Information

Honeywell compliance with Directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

Australia/NZ

C-Tick Statement

Statement indicating conformity to AS/NZS 3548 EMC requirement.

Russia

Gost-R Certificate

Certificate indicating compliance with Gost-R requirements.

International

LED Safety Statement

Scanner LEDs tested and classified as EXEMPT RISK GROUP per IEC 62471:2006.

CB Scheme

Laser Safety Statement

Solids and Water Protection

Granit 1911i IP65 Rating

Granit 1911i has IP65 rating, protected against dust and dripping water.

Chapter 1 - Getting Started

About This Manual

Provides installation and programming instructions for various Honeywell scanners.

Unpacking Your Device

Steps for safely unpacking the scanner and checking contents.

Connecting the Device

Instructions on connecting the scanner to a computer via USB, Keyboard Wedge, and RS232.

Chapter 2 - Programming the Interface

Introduction

Describes how to program the scanner for the desired interface.

Programming the Interface - Plug and Play

Instant scanner setup for common interfaces using Plug and Play bar codes.

Keyboard Wedge

Configures scanner for IBM PC AT and compatible keyboard wedge interface.

Laptop Direct Connect

Enables scanner operation with laptop's integral keyboard.

RS232 Serial Port

RS485

RS485 Packet Mode

Allows breaking up large bar code data into smaller packets for IBM POS terminals.

RS485 Packet Length

Specifies the data 'packet' size sent to the host when using Packet mode.

USB IBM SurePos

USB PC or Macintosh Keyboard

USB HID

USB Serial

CTS/RTS Emulation

Controls CTS/RTS emulation for serial communication.

ACK/NAK Mode

Configures ACK/NAK mode for scanner communication.

Remote MasterMind™ for USB

Verifone® Ruby Terminal Default Settings

Gilbarco® Terminal Default Settings

Honeywell Bioptic Aux Port Configuration

Datalogic™ Magellan® Aux Port Configuration

NCR Bioptic Aux Port Configuration

Wincor Nixdorf Terminal Default Settings

Wincor Nixdorf Beetle™ Terminal Default Settings

Keyboard Country Layout

Keyboard Style

Keyboard Conversion

Control Character Output

Keyboard Modifiers

RS232 Baud Rate

Sets the data transmission rate between scanner and terminal.

RS232 Word Length: Data Bits, Stop Bits, and Parity

RS232 Receiver Time-Out

RS232 Handshaking

Flow Control, No Timeout

Scanner asserts RTS when data is ready, waits indefinitely for CTS.

Two-Direction Flow Control

Scanner asserts RTS for host transmit; host asserts CTS for device transmit.

Flow Control with Timeout

Scanner asserts RTS, waits for CTS with a delay; resets if timeout expires.

RS232 Timeout

XON/XOFF

ACK/NAK

Chapter 3 - Cordless System Operation

How the Cordless Charge Base/Access Point Works

Explains the function of cordless charge base or Access Point for scanner link and data exchange.

Linking the Scanner to a Charge Base

Procedure to link a scanner to a charge base for initial setup and charging.

Linking the Scanner to an Access Point

Communication Between the Cordless System and the Host

Programming the Scanner and Base or Access Point

RF (Radio Frequency) Module Operation

System Conditions

Linking Process

Scanner battery status check and automatic detection for linking to base.

Scanner Is Out of Range

Describes scanner losing communication with base/Access Point and resulting error tone.

Scanner Is Moved Back Into Range

Procedure for scanner relinking when it returns within range.

Out of Range and Back into Range with Batch Mode On

Scanner stores symbols out of range and sends them when back in range.

Page Button

About the Battery

Charging Information

Battery Recommendations

Safety Precautions for Lithium Batteries

Proper Disposal of the Battery

Chapter 4 - Input/Output Settings

Power Up Beeper

Configures scanner and base to beep upon power up.

Beep on BEL Character

Configures scanner to beep upon receiving a BEL character from host.

Trigger Click

Enables or disables an audible click when the scanner trigger is pressed.

Good Read and Error Indicators

Beeper – Good Read

Programs beeper On or Off for good read indications.

Beeper Volume – Good Read

Modifies the volume of the beep emitted on a good read.

Beeper Pitch – Good Read

Modifies the pitch (frequency) of the beep emitted on a good read.

Vibrate – Good Read

Vibrate Duration

Beeper Pitch – Error

Beeper Duration – Good Read

LED – Good Read

Number of Beeps – Good Read

Number of Beeps – Error

Beeper Volume Max

Good Read Delay

User-Specified Good Read Delay

Manual Trigger Modes

LED Illumination - Manual Trigger

Serial Trigger Mode

Read Time-Out

Presentation Mode

LED Illumination - Presentation Mode

Presentation LED Behavior after Decode

Presentation Sensitivity

Presentation Centering

In-Stand Sensor Mode

CodeGate®

Streaming Presentation™ Mode

Streaming Presentation In-Stand Programming

Mobile Phone Read Mode

Hands Free Time-Out

Reread Delay

User-Specified Reread Delay

Illumination Lights

Aimer Delay

User-Specified Aimer Delay

Scanner Time-Out

Aimer Mode

Centering

Preferred Symbology

High Priority Symbology

Specifies the high priority symbology by scanning its Hex value.

Low Priority Symbology

Specifies low priority symbology by scanning its Hex value.

Preferred Symbology Time-out

Sets the time period scanner searches for high priority bar code after low priority.

Preferred Symbology Default

Output Sequence Overview

Require Output Sequence

Ensures all output data conforms to an edited sequence.

Output Sequence Editor

Programs scanner to output data in desired order, regardless of scan order.

Partial Sequence

Multiple Symbols

No Read

Video Reverse

Working Orientation

Chapter 5 - Data Editing

Prefix/Suffix Overview

Sends additional user-defined data before or after scanned bar code data.

Points to Keep In Mind

Notes on building message strings and default settings.

To Add a Prefix or Suffix

Step-by-step guide to adding prefixes or suffixes to scanned data.

Example: Add a Suffix to a specific symbology

To Clear One or All Prefixes or Suffixes

Function Code Transmit

Intercharacter, Interfunction, and Intermessage Delays

Intercharacter Delay

User Specified Intercharacter Delay

Interfunction Delay

Intermessage Delay

Chapter 6 - Data Formatting

Data Format Editor Introduction

Allows changing scanner output by inserting characters into bar code data.

Add a Data Format

Steps to enter and save data formats for primary or alternate use.

Terminal ID Table

Data Format Editor Commands

Send Commands

Commands for sending characters or strings based on input message and criteria.

Other Programming Selections

Clear One Data Format

Deletes a single data format for one symbology.

Clear all Data Formats

Clears all data formats.

Chapter 7 - Symbologies

All Symbologies

Enables or disables decoding of all allowable symbologies.

Message Length Description

Sets valid reading length for symbologies to reduce misreads.

Codabar

Codabar On/Off

Enables or disables Codabar symbology decoding.

Codabar Start/Stop Characters

Transmits or does not transmit Codabar start/stop characters.

Codabar Check Character

Programs scanner to read Codabar bar codes with specific modulo check characters.

Codabar Concatenation

Codabar Message Length

Code 39

Code 39 On/Off

Enables or disables Code 39 symbology decoding.

Code 39 Start/Stop Characters

Transmits or does not transmit Code 39 start/stop characters.

Code 39 Check Character

Programs scanner to read Code 39 bar codes with specific check characters.

Code 39 Message Length

Code 39 Append

Code 32 Pharmaceutical (PARAF)

Full ASCII

Code 39 Code Page

Interleaved 2 of 5

Interleaved 2 of 5 On/Off

Enables or disables Interleaved 2 of 5 symbology decoding.

Check Digit

Programs scanner to read Interleaved 2 of 5 with or without check digit.

Interleaved 2 of 5 Message Length

NEC 2 of 5

NEC 2 of 5 On/Off

Enables or disables NEC 2 of 5 symbology decoding.

Check Digit

Programs scanner to read NEC 2 of 5 with or without check digit.

NEC 2 of 5 Message Length

Code 93

Code 93 On/Off

Enables or disables Code 93 symbology decoding.

Code 93 Message Length

Changes the minimum and maximum message length for Code 93.

Code 93 Append

Appends data from several Code 93 bar codes before transmitting.

Code 93 Code Page

Straight 2 of 5 Industrial (three-bar start/stop)

Straight 2 of 5 Industrial On/Off

Enables or disables Straight 2 of 5 Industrial symbology.

Straight 2 of 5 Industrial Message Length

Changes message length for Straight 2 of 5 Industrial symbology.

Straight 2 of 5 IATA (two-bar start/stop)

Straight 2 of 5 IATA On/Off

Enables or disables Straight 2 of 5 IATA symbology.

Straight 2 of 5 IATA Message Length

Changes message length for Straight 2 of 5 IATA symbology.

Matrix 2 of 5

Matrix 2 of 5 On/Off

Enables or disables Matrix 2 of 5 symbology decoding.

Matrix 2 of 5 Message Length

Changes message length for Matrix 2 of 5 symbology.

Code 11

Code 11 On/Off

Enables or disables Code 11 symbology decoding.

Check Digits Required

Sets whether 1 or 2 check digits are required for Code 11.

Code 11 Message Length

Code 128

Code 128 On/Off

Enables or disables Code 128 symbology decoding.

ISBT 128 Concatenation

Standard for communicating critical blood information in a uniform manner.

Code 128 Message Length

Changes message length for Code 128 symbology.

Code 128 Append

Code 128 Code Page

GS1-128

GS1-128 On/Off

Enables or disables GS1-128 symbology.

GS1-128 Message Length

Changes message length for GS1-128 symbology.

Telepen

Telepen On/Off

Enables or disables Telepen symbology.

Telepen Output

Configures Telepen output for AIM or Original Telepen.

Telepen Message Length

Changes message length for Telepen symbology.

UPC-A

UPC-A On/Off

Enables or disables UPC-A symbology.

UPC-A Check Digit

Specifies whether check digit is transmitted at the end of scanned UPC-A data.

UPC-A Number System

Programs whether numeric system digit is transmitted at the beginning of scanned UPC-A data.

UPC-A Addenda

UPC-A Addenda Required

UPC-A Addenda Separator

UPC-A/EAN-13 with Extended Coupon Code

Coupon GS1 DataBar Output

UPC-E0

UPC-E0 On/Off

Enables or disables UPC-E0 symbology decoding.

UPC-E0 Expand

Expands UPC-E code to 12 digit, UPC-A format.

UPC-E0 Addenda Required

UPC-E0 Addenda Separator

UPC-E0 Check Digit

UPC-E0 Leading Zero

UPC-E0 Addenda

UPC-E1

EAN/JAN-13

EAN/JAN-13 On/Off

Enables or disables EAN/JAN-13 symbology.

Convert UPC-A to EAN-13

Converts UPC-A bar codes to 13 digit EAN-13 codes.

EAN/JAN-13 Check Digit

EAN/JAN-13 Addenda

EAN/JAN-13 Addenda Required

EAN/JAN-13 Addenda Separator

ISBN Translate

EAN/JAN-8

EAN/JAN-8 On/Off

Enables or disables EAN/JAN-8 symbology.

EAN/JAN-8 Check Digit

Specifies whether check digit is transmitted at the end of scanned EAN/JAN-8 data.

EAN/JAN-8 Addenda

EAN/JAN-8 Addenda Required

EAN/JAN-8 Addenda Separator

MSI

MSI On/Off

Enables or disables MSI symbology.

MSI Check Character

Programs scanner to read MSI bar codes with specified type check characters.

MSI Message Length

GS1 DataBar Omnidirectional

GS1 DataBar Omnidirectional On/Off

Enables or disables GS1 DataBar Omnidirectional symbology.

GS1 DataBar Limited

GS1 DataBar Limited On/Off

Enables or disables GS1 DataBar Limited symbology.

GS1 DataBar Expanded

GS1 DataBar Expanded On/Off

Enables or disables GS1 DataBar Expanded symbology.

GS1 DataBar Expanded Message Length

Changes message length for GS1 DataBar Expanded symbology.

Trioptic Code

Codablock A

Codablock A On/Off

Enables or disables Codablock A symbology.

Codablock A Message Length

Changes message length for Codablock A symbology.

Codablock F

Codablock F On/Off

Enables or disables Codablock F symbology.

Codablock F Message Length

Changes message length for Codablock F symbology.

PDF417

PDF417 On/Off

Enables or disables PDF417 symbology.

PDF417 Message Length

Changes message length for PDF417 symbology.

MacroPDF417

MicroPDF417

MicroPDF417 On/Off

Enables or disables MicroPDF417 symbology.

MicroPDF417 Message Length

Changes message length for MicroPDF417 symbology.

GS1 Composite Codes

UPC/EAN Version

GS1 Composite Code Message Length

GS1 Emulation

TCIF Linked Code 39 (TLC39)

QR Code

QR Code On/Off

Applies to both QR Code and Micro QR Code; enables or disables decoding.

QR Code Message Length

Changes message length for QR Code.

QR Code Append

QR Code Page

Data Matrix

Data Matrix On/Off

Enables or disables Data Matrix symbology.

Data Matrix Message Length

Changes message length for Data Matrix.

Data Matrix Append

Data Matrix Code Page

MaxiCode

MaxiCode On/Off

Enables or disables MaxiCode symbology.

MaxiCode Message Length

Changes message length for MaxiCode symbology.

Aztec Code

Aztec Code On/Off

Enables or disables Aztec Code symbology.

Aztec Code Message Length

Changes message length for Aztec Code.

Aztec Append

Aztec Code Page

Chinese Sensible (Han Xin) Code

Han Xin Code On/Off

Enables or disables Han Xin Code symbology.

Han Xin Code Message Length

Changes message length for Han Xin Code.

Postal Codes - 2D

Single 2D Postal Codes

Lists and enables individual 2D postal code selections.

Combination 2D Postal Codes

Planet Code Check Digit

Postnet Check Digit

Australian Post Interpretation

Postal Codes - Linear

China Post (Hong Kong 2 of 5)

Default settings for China Post (Hong Kong 2 of 5) symbology.

China Post (Hong Kong 2 of 5) On/Off

Enables or disables China Post (Hong Kong 2 of 5) symbology.

China Post (Hong Kong 2 of 5) Message Length

Korea Post

Korea Post

Default settings for Korea Post symbology.

Korea Post On/Off

Enables or disables Korea Post symbology.

Korea Post Message Length

Korea Post Check Digit

Chapter 8 - Imaging Commands

Single-Use Basis

Imaging commands with modifiers take effect for single capture, reverting to defaults.

Command Syntax

Describes how to combine multiple modifiers and commands in a sequence.

Step 1 - Take a Picture Using IMGSNP

Image Snap - IMGSNP

Command to capture an image, with various modifiers for image look.

IMGSNP Modifiers

Details modifiers for Image Snap: P-Imaging Style, B-Beeper, T-Wait for Trigger, L-LED State.

E - Exposure

G - Gain

W - Target White Value

D - Delta for Acceptance

U - Update Tries

% - Target Set Point Percentage

Step 2 - Ship a Picture Using IMGSHP

Image Ship - IMGSHP

Command to transmit captured image data to the host.

IMGSHP Modifiers

Details modifiers for Image Ship: A-Infinity Filter.

C - Compensation

D - Pixel Depth

F - File Format

E - Edge Sharpen

F - File Format

H - Histogram Stretch

I - Invert Image

IF- Noise Reduction

IR - Image Rotate

J - JPEG Image Quality

K - Gamma Correction

L, R, T, B, M - Image Cropping

P - Protocol

S - Pixel Ship

U - Document Image Filter

Chapter 9 - Interface Keys

Keyboard Function Relationships

Keyboard Function Code, Hex/ASCII Value, and Full ASCII CTRL+ relationships.

Supported Interface Keys

Table mapping ASCII/HEX values to PC/Mac keyboard and interface keys.

Chapter 10 - Utilities

To Add a Test Code I.D. Prefix to All Symbologies

Temporarily enables transmission of Code I.D. before decoded symbology.

Show Decoder Revision

Outputs the decoder revision information.

Show Scan Driver Revision

Outputs the scan driver revision, which controls image capture.

Show Software Revision

Outputs current software revision, serial number, and other product information.

Show Data Format

Test Menu

TotalFreedom

Application Plug-Ins (Apps)

EZConfig-Scanning Introduction

EZConfig-Scanning Operations

Scan Data

Scans bar codes, displays data in window, sends serial commands, receives responses.

Configure

Displays scanner programming and configuration data in a tree structure.

Imaging

Provides image-related functions: capture, manipulate, and transfer images.

Installing EZConfig-Scanning from the Web

Chapter 11 - Serial Programming Commands

Conventions

Defines conventions used for menu and query command descriptions.

Menu Command Syntax

Explains the syntax for menu commands including prefix, tag, subtag, and data.

Query Commands

Field Usage

Explains usage for Tag, SubTag, and Data fields in query commands.

Concatenation of Multiple Commands

Describes issuing multiple commands within one sequence using separators.

Responses

Examples of Query Commands

Trigger Commands

Resetting the Custom Defaults

Menu Commands

Product Default Settings

Table listing default settings for product configuration.

Programming the Interface

Table listing Plug and Play codes for interface programming.

Plug and Play Codes: RS485

Plug and Play Codes: IBM SurePos

Plug and Play Codes: USB

Program Keyboard Country

Program Keyboard Country

Program Keyboard Country

Keyboard Conversion

Keyboard Style

Control Character Output

Keyboard Modifiers

Baud Rate

Word Length: Data Bits, Stop Bits, and Parity

RS232 Receiver Time-out

RS232 Handshaking

Scanner-Bioptic Packet Mode

Scanner-Bioptic ACK/NAK Mode

Scanner-Bioptic ACK/NAK Timeout

Cordless System Operation

Base Power Communication Indicator

Controls display of power indicator on base or Access Point.

Reset Scanner

Reboots scanner and relinks with base or Access Point.

Scanning While in Base Cradle

Allows scanning bar codes while scanner is in base cradle.

Paging Mode

Paging Pitch

Beeper Pitch - Base Error

Number of Beeps - Base Error

Scanner Report

Scanner Address

Base Address

Scanner Modes

Charge Only Mode

Charges scanner without linking to base, retaining existing link.

Charge and Link Mode

Charges scanner and links it to the base.

Linked Modes

Unlinking the Scanner

Override Locked Scanner

Out-of-Range Alarm

Alarm Sound Type

Scanner Power Time-Out Timer

Flexible Power Management

Reset

Reset Base

Resets the base and waits for scanner to unlink and relink.

Reset Scanner

Resets the scanner and waits for base/Access Point to unlink and relink.

Batch Mode

Automatic Batch Mode

Stores bar code data when scanner is out of range, transmits automatically when back in range.

Inventory Batch Mode

Stores bar code data regardless of range; transmits via base or Access Point.

Persistent Batch Mode

Stores data, transmits, and retains it in scanner for multiple transmissions.

Batch Mode Beep

Batch Mode Storage

Batch Mode Quantity

Quantity Codes

Batch Mode Output Order

Total Records

Delete Last Code

Clear All Codes

Transmit Records to Host

Batch Mode Transmit Delay

Multiple Scanner Operation

Scanner Name

Application Work Groups

Application Work Group Selection

Resetting the Factory Defaults: All Application Work Groups

Resetting the Custom Defaults: All Application Work Groups

Using the Scanner with Bluetooth Devices

Bluetooth HID Keyboard Connect

Pairs scanner with Bluetooth devices for keyboard input.

Bluetooth HID Keyboard Disconnect

Bluetooth Serial Port - PCs/Laptops

PDAs/Mobility Systems Devices

Changing the Scanner’s Bluetooth PIN Code

Minimizing Bluetooth/ISM Band Network Activity

Auto Reconnect Mode

Maximum Link Attempts

Relink Time-Out

Bluetooth/ISM Network Activity Examples

Host Acknowledgment

Host ACK Responses

Chapter 12 - Product Specifications

Xenon 1900/1910 Corded Scanner Product Specifications

Technical specifications for Xenon 1900/1910 corded scanner, including dimensions, LED, aiming, and power.

Xenon 1902/1912 Cordless Scanner Product Specifications

Technical specifications for Xenon 1902/1912 cordless scanner, including dimensions, LED, aiming, and radio.

Granit 1910i Industrial Corded Scanner Product Specifications

Technical specifications for Granit 1910i corded scanner, including dimensions, LED, aiming, and voltage.

Granit 1911i Industrial Cordless Scanner Product Specifications

Technical specifications for Granit 1911i cordless scanner, including dimensions, LED, aiming, and radio.

CCB01-010BT Charge Base Product Specifications

Technical specifications for CCB01-010BT charge base, including dimensions, voltage, radio, and temperature.

CCB02-100BT Industrial Charge Base Product Specifications

Technical specifications for CCB02-100BT industrial charge base, including dimensions, voltage, radio, and temperature.

Depth of Field Charts

Typical performance charts for Xenon B&W scanner across different symbologies and resolutions.

Xenon B&W Scanner Guaranteed Performance

Xenon Color Scanner (Model COL) Typical Performance

Xenon Color Scanner (Model COL) Guaranteed Performance

Granit Scanner Typical Performance

Granit Scanner Guaranteed Performance

Standard Connector Pinouts

Keyboard Wedge

Pin assignments for 10 Pin RJ41 Modular Plug connecting scanner to base.

Serial Output

Pin assignments for 10 Pin RJ41 Modular Plug connecting scanner to base.

RS485 Output

USB

Chapter 13 - Maintenance

Repairs

Services and upgrades must be performed by an authorized service center.

Maintenance

Guidelines for periodic checks to ensure dependable operation.

Cleaning the Scanner

Instructions for cleaning scanner housing with soft cloth or tissue.

Cleaning the Window

Instructions for cleaning scanner window to maintain performance.

Health Care Housing

Description of external plastic housing resistant to harsh chemicals.

Important Cleaning Solutions

Inspecting Cords and Connectors

Replacing Cables in Corded Scanners

Replacing a Xenon Interface Cable

Procedure for replacing the interface cable on a Xenon scanner.

Replacing a Granit Interface Cable

Procedure for replacing the interface cable on a Granit scanner.

Replacing Cables and Batteries in Cordless Systems

Replacing an Interface Cable in a Base

Procedure for replacing interface cable in CCB01-010BT and CCB02-100BT bases.

Changing a Xenon Scanner Battery

Changing a Granit Scanner Battery

Troubleshooting a Corded Scanner

Is the power on? Is the aimer on?

Check power connection, host power, and trigger function if aimer is not illuminated.

Is the scanner having trouble reading your symbols?

Is the bar code displayed but not entered into the application?

Does the scanner read the bar code incorrectly?

Troubleshooting a Cordless System

Troubleshooting a Base

Guidelines for isolating base functionality problems.

Is the red LED on?

Is the green LED on?

Troubleshooting a Cordless Scanner

Is the scanner having trouble reading your symbols?

Check symbol quality and enablement if scanner reads symbols poorly.

Is the bar code displayed but not entered into the application?

Check suffix programming if bar code data requires key entry.

Does the scanner read the bar code incorrectly?

Check terminal interface and symbology settings if data is read incorrectly.

Chapter 14 - Customer Support

Technical Assistance

Contact methods for installation or troubleshooting assistance.

Product Service and Repair

Information on obtaining warranty or non-warranty service through service centers.

Limited Warranty

Warranty terms covering product defects in materials and workmanship.

Warranty Period Details

Appendix A - Reference Charts

Symbology Charts

Reference for AIM modifier characters and Honeywell IDs for symbologies.

Linear Symbologies

Lists AIM and Honeywell IDs and modifiers for linear symbologies.

2D Symbologies

Postal Symbologies

ASCII Conversion Chart (Code Page 1252)

Lower ASCII Reference Table

Extended ASCII Characters

ISO 2022/ISO 646 Character Replacements

Related product manuals