11 - 1
11
Serial Programming Commands
The serial programming commands can be used in place of the programming
bar codes. Both the serial commands and the programming bar codes will pro-
gram the scanner. For complete descriptions and examples of each serial pro-
gramming command, refer to the corresponding programming bar code in this
manual.
The device must be set to an RS232 interface (see page 2-2). The following
commands can be sent via a PC COM port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter
A label representing the actual value you should send as part of a
command.
[
option
]An optional part of a command.
{Data}Alternatives in a command.
boldNames of menus, menu commands, buttons, dialog boxes, and windows
that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix [:Name:] Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […]
Storage
PrefixThree ASCII characters: SYN M CR (ASCII 22,77,13).
:Name:To send information to the scanner (with the base connected to host), use
:Xenon: The default factory setting for a Xenon scanner is Xenon scanner.
This setting is changed by using the BT_NAM command, which accepts
alphanumeric values. If the name is not known, a wildcard (*) can be used
:*:.
Note: Since the base stores all work group settings and transfers to them to
scanner once they are linked, changes are typically done to the base and
not to the scanner.
Tag A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTagA 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the RS232
baud rate is BAD.
DataThe new value for a menu setting, identified by the Tag and SubTag.

Table of Contents

Other manuals for Honeywell XENON 1900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XENON 1900 and is the answer not in the manual?

Honeywell XENON 1900 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Linear (1D) barcodes supported-
Standard interfacesUSB, Keyboard wedge, RS-232, RS-485
Connectivity technologyWired
Input voltage4 - 5.5 V
Power consumption450 mA
Power source typeDC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
ShockproofYes
Product colorBlack
International Protection (IP) codeIP41
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth104 mm
Width71 mm
Height160 mm
Weight147 g